A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sputter sample preparation for ion beam delivery of radium-223 at ATLAS. | LitMetric

Sputter sample preparation for ion beam delivery of radium-223 at ATLAS.

Rev Sci Instrum

Physics Division, Argonne National Laboratory, Lemont, Illinois 60439, USA.

Published: June 2023

A radium-223 ion beam was delivered to an experiment from the electron cyclotron resonance ion source, ECR2, at the Argonne Tandem Linac Accelerator System (ATLAS). The radium-223 material was in a nitrate salt form within a vial, prior to being converted to a usable sputter sample. The sputter sample was produced using a new sample preparation method, where the radium nitrate was dissolved into a solution and pipetted onto pressed aluminum powder. This sample was then allowed to dry, distributing the radium-223 material throughout the sputter sample. Ion source operation using the radium sputter sample is described with the operating parameters listed. The intensity and energy requirements for this ion beam were 1 × 106 particles/s and 1.07 GeV, respectively. Because the intensity is relatively low compared to most experiments at ATLAS, previously developed accelerator mass spectrometry methods were used Scott et al. [Rev. Sci. Instrum. 87, 02A732 (2016)] to avoid the need for tuning of the low-intensity beam of interest. Handling of the radium material, as well as loading and unloading of the sputter sample from ECR2, required collaboration with Health Physics. Procedures were used and dry runs were carried out before, during, and after the experiment to ensure the safety of the workers. The processes used and lessons learned are described within.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0137098DOI Listing

Publication Analysis

Top Keywords

sputter sample
24
ion beam
12
sample preparation
8
atlas radium-223
8
ion source
8
radium-223 material
8
sample
7
sputter
6
ion
5
preparation ion
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!