Importance: Improved strategies are needed to decrease opioid use after cesarean delivery but still adequately control postoperative pain. Although transcutaneous electrical stimulation devices have proven effective for pain control after other surgical procedures, they have not been tested as part of a multimodal analgesic protocol after cesarean delivery, the most common surgical procedure in the United States.

Objective: To determine whether treatment with a noninvasive high-frequency electrical stimulation device decreases opioid use and pain after cesarean delivery.

Design, Setting, And Participants: This triple-blind, sham-controlled randomized clinical trial was conducted from April 18, 2022, to January 31, 2023, in the labor and delivery unit at a single tertiary academic medical center in Ohio. Individuals were eligible for the study if they had a singleton or twin gestation and underwent a cesarean delivery. Of 267 people eligible for the study, 134 (50%) were included.

Intervention: Participants were randomly assigned in a 1:1 ratio to a high-frequency (20 000 Hz) electrical stimulation device group or to an identical-appearing sham device group and received 3 applications at the incision site in the first 20 to 30 hours postoperatively.

Main Outcomes And Measures: The primary outcome was inpatient postoperative opioid use, measured in morphine milligram equivalents (MME). Secondary outcomes included pain scores, measured with the Brief Pain Inventory questionnaire (scale, 0-10, with 0 representing no pain), MME prescribed at discharge, and receipt of additional opioid prescriptions in the postpartum period. Normally distributed data were assessed using t tests; otherwise via Mann-Whitney or χ2 tests as appropriate. Analyses were completed following intention-to-treat principles.

Results: Of 134 postpartum individuals who underwent a cesarean delivery (mean [SD] age, 30.5 [4.6] years; mean [SD] gestational age at delivery, 38 weeks 6 days [8 days]), 67 were randomly assigned to the functional device group and 67 to the sham device group. Most were multiparous, had prepregnancy body mass index (calculated as weight in kilograms divided by height in meters squared) higher than 30, were privately insured, and received spinal anesthesia. One participant in the sham device group withdrew consent prior to treatment. Individuals assigned to the functional device used significantly less opioid medication prior to discharge (median [IQR], 19.75 [0-52.50] MME) than patients in the sham device group (median [IQR], 37.50 [7.50-67.50] MME; P = .046) and reported similar rates of moderate to severe pain (85% vs 91%; relative risk [RR], 0.77 [95% CI, 0.55-1.29]; P = .43) and mean pain scores (3.59 [95% CI, 3.21-3.98] vs 4.46 [95% CI, 4.01-4.92]; P = .004). Participants in the functional device group were prescribed fewer MME at discharge (median [IQR], 82.50 [0-90.00] MME vs 90.00 [75.00-90.00] MME; P < .001). They were also more likely to be discharged without an opioid prescription (25% vs 10%; RR, 1.58 [95% CI, 1.08-2.13]; P = .03) compared with the sham device group. No treatment-related adverse events occurred in either group.

Conclusions And Relevance: In this randomized clinical trial of postoperative patients following cesarean delivery, use of a high-frequency electrical stimulation device as part of a multimodal analgesia protocol decreased opioid use in the immediate postoperative period and opioids prescribed at discharge. These findings suggest that the use of this device may be a helpful adjunct to decrease opioid use without compromising pain control after cesarean delivery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10589807PMC
http://dx.doi.org/10.1001/jamanetworkopen.2023.38188DOI Listing

Publication Analysis

Top Keywords

device group
28
cesarean delivery
16
sham device
16
electrical stimulation
12
functional device
12
median [iqr]
12
pain
9
device
9
randomized clinical
8
clinical trial
8

Similar Publications

Microelectronic Structure and Doping Nonuniformity of Phosphorus-Doped CdSeTe Solar Cells.

ACS Appl Mater Interfaces

January 2025

National Renewable Energy Laboratory, Golden, Colorado 80401, United States.

Optimizing group-V doping and Se alloying are two main focuses for advancing CdTe photovoltaic technology. We report on nanometer-scale characterizations of microelectronic structures of phosphorus (P)-doped CdSeTe devices using a combination of two atomic force microscopy-based techniques, namely, Kelvin probe force microscopy (KPFM) and scanning spreading resistance microscopy (SSRM). KPFM on device cross-section images distribution of the potential drop across the device.

View Article and Find Full Text PDF

Objectives: We aim to evaluate the safety and effectiveness of the Zenith Dissection Endovascular System (ZDES; Zenith TX2 Dissection Endovascular Graft with Pro-Form and Zenith Dissection Endovascular Stent), which uses a proximal stent graft along with a distal bare metal stent compared to traditional stent grafts in the repair of acute, complicated Type B Aortic Dissection (AcTBAD).

Methods: This retrospective study reviews the medical charts of 32 patients with AcTBAD repaired at a single urban academic medical center. 16 of these AcTBAD cases were repaired with the ZDES (87.

View Article and Find Full Text PDF

Herein, we report the isolation of pyridine moiety-functionalized SiNSi pincer-based bis-silylene ligand () and its reactivity toward various halide precursors (X = Br and I) of group 13 elements (M = Al, Ga, and In). This gave us straightforward access to the SiNSi pincer-coordinated group 13 cations (-). These complexes are duly characterized by single-crystal X-ray diffraction studies, multinuclear magnetic resonance spectroscopy (H, C, and Si), and high-resolution mass spectrometry techniques.

View Article and Find Full Text PDF

Aim: To assess the safety and efficacy of alfapump on ascites control and quality of life in these patients.

Methods: Patients with cirrhosis and RA requiring ≥2 TPs 30 days prior were enrolled and followed for 24 months (M) post-implant. Primary efficacy endpoint assessed at 6M was reduction in paracentesis requirement; safety end point was device related adverse events resulting in intervention, explant, or death.

View Article and Find Full Text PDF

Intracellular delivery of proteins has attracted significant interest in biological research and cancer treatment, yet it continues to face challenges due to the lack of effective delivery approaches. Herein, we developed an efficient strategy cationic α-helical polypeptide-mediated anionic proprotein delivery. The protein was reversibly modified with adenosine triphosphate dynamic covalent chemistry to prepare an anionic proprotein (A-protein) with abundant phosphate groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!