A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Case report: Total hip replacement using Innoplant system in a dog with chronic hip luxation and contralateral pelvic limb amputation. | LitMetric

A 6-year-old female neutered Border Collie presented with an inability to walk. The patient had undergone pelvic limb amputation over a year prior. Orthopedic examination revealed discomfort during hip manipulation, and radiographic examination revealed chronic hip luxation. Total hip replacement was performed using the InnoPlant system, which includes modular screw-in cementless pieces to improve implant stability. Cage rest was for the first four postoperative weeks. Subsequently, assistance was provided while standing until the patient could stand unassisted at 10 postoperative weeks. The clinical and radiological outcomes were excellent 3 months postoperatively. Since it is a new system, there are no data regarding the use of the components of the Innoplant system in dogs with a contralateral amputated pelvic limb. This is the first report describing the use of the Innoplant system for total hip replacement in a dog with a contralateral amputated pelvic limb. Based on the clinical outcomes of this case, the use of an Innoplant prosthesis can be an effective treatment option for dogs with contralateral amputated limbs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10582927PMC
http://dx.doi.org/10.3389/fvets.2023.1219617DOI Listing

Publication Analysis

Top Keywords

innoplant system
16
pelvic limb
16
total hip
12
hip replacement
12
contralateral amputated
12
chronic hip
8
hip luxation
8
limb amputation
8
examination revealed
8
postoperative weeks
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!