A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous detection of greenhouse gases CH and CO based on a dual differential photoacoustic spectroscopy system. | LitMetric

In addition to the atmospheric measurement, detection of dissolved carbon oxides and hydrocarbons in a water region is also an important aspect of greenhouse gas monitoring, such as CH and CO. The first step of measuring dissolved gases is the separation process of water and gases. However, slow degassing efficiency is a big challenge which requires the gas detection technology itself with low gas consumption. Photoacoustic spectroscopy (PAS) is a good choice with advantages of high sensitivity, low gas consumption, and zero background, which has been rapidly developed in recent years and is expected to be applied in the field of dissolved gas detection. In this study, a miniaturized differential photoacoustic cell with a volume of 7.9 mL is designed for CH and CO detection, and a dual differential method with four microphones is proposed to enhance the photoacoustic signal. What we believe to be a new method increases photoacoustic signal by 4 times and improves the signal to noise ratio (SNR) over 10 times compared with the conventional single-microphone mode. Two distributed feedback (DFB) lasers at 1651 nm and 2004nm are employed to construct the PAS system for CH and CO detection respectively. Wavelength modulation spectroscopy (WMS) and 2 harmonic demodulation techniques are applied to further improve the SNR. As a result, sensitivity of 0.44 ppm and 7.39 ppm for CH and CO are achieved respectively with an integration time of 10 s. Allan deviation analysis indicates that the sensitivity can be further improved to 42 ppb (NNEA=4.7×10cmWHz) for CH and 0.86 ppm (NNEA=5.3×10cmWHz) for CO when the integration time is extended to 1000 s.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.503454DOI Listing

Publication Analysis

Top Keywords

dual differential
8
differential photoacoustic
8
photoacoustic spectroscopy
8
gas detection
8
low gas
8
gas consumption
8
photoacoustic signal
8
integration time
8
photoacoustic
5
detection
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!