We demonstrated a new method of fabricating a stretchable antenna by injecting liquid metal (LM) into a femtosecond-laser-ablated embedded hydrogel microchannel, and realized miniaturization of a stretchable dipole antenna based on hydrogel substrate. Firstly, symmetrical microchannels with two equal and linear branches were formed by a femtosecond laser in the middle of a hydrogel substrate, and then were filled with LM by use of a syringe needle. Using this method, a stretchable LM-dipole antenna with each dimension of  24 mm × 0.6 mm × 0.2 mm separated by a 2-mm gap, was formed in the middle of a 70 mm × 12 mm × 7 mm hydrogel slab. Since the polyacrylamide (PAAm) hydrogel contained ∼ 95 wt % deionized water with a high permittivity of 79 in the 0.5 GHz - 1.5 GHz range, the hydrogel used to prepare the flexible antenna can be considered as distilled water boxes. Experiments and simulations showed that a 5-cm-long LM-dipole embedded in hydrogel resonated at approximately 927.5 MHz with an S value of about - 12.6 dB and omnidirectional radiation direction. Benefiting from the high permittivity of the hydrogel, the dipole length was downsized by about half compared with conventional polymer substrates at the same resonant frequency. By varying the applied strain from 0 to 48%, the resonant frequency of the hydrogel/LM dipole antenna can be tuned from 770.3 MHz to 927.0 MHz. This method provides a simple and scalable technique for the design and preparation of LM-pattern microstructures in hydrogels, and has potential applications in hydrogel-based soft electronic device.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.496360DOI Listing

Publication Analysis

Top Keywords

femtosecond laser
8
hydrogel
8
embedded hydrogel
8
dipole antenna
8
hydrogel substrate
8
high permittivity
8
resonant frequency
8
antenna
6
fabrication flexible
4
stretchable
4

Similar Publications

Femtosecond Laser Arcuate Keratotomy vs Toric Intraocular Lens Implantation in Cataract Surgery: A Randomized Clinical Trial.

JAMA Ophthalmol

January 2025

Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Zhejiang Provincial Key Laboratory of Ophthalmology, Zhejiang Provincial Clinical Research Center for Eye Diseases, Zhejiang Provincial Engineering Institute on Eye Diseases, Hangzhou, China.

Importance: After cataract surgery, postoperative residual astigmatism can influence a patient's visual quality and satisfaction. Finding ways to minimize this astigmatism is important.

Objective: To compare the clinical outcomes of femtosecond laser arcuate keratotomy (FSAK) and toric intraocular lens (TIOL) implantation for astigmatism correction in patients undergoing femtosecond laser-assisted cataract surgery.

View Article and Find Full Text PDF

We demonstrate a high-performance ultrafast broadband time-resolved photoluminescence (TRPL) system based on the transient grating photoluminescence spectroscopy (TGPLS) technique. The core of the system is a Kerr effect-induced transient grating (TG) optical gate driven by high repetition rate ultrashort laser pulses at 1030 nm with micro-Joule pulse energy. Satisfying the demands of spectroscopy applications, the setup achieves high sensitivity, rapid data acquisition, ultrafast time resolution, and a wide spectral window from ultraviolet to near-infrared.

View Article and Find Full Text PDF

Femtosecond laser-assisted large-diameter lamellar corneal-limbal keratoplasty in ocular chemical burns.

Am J Ophthalmol Case Rep

March 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China.

Purpose: This study highlights the feasibility of femtosecond laser-assisted large-diameter lamellar corneal-limbal keratoplasty and its efficacy in the treatment of ocular surface failure caused by bilateral ocular chemical injury.

Observations: The series included 3 patients with ocular surface failure caused by bilateral ocular chemical burns. After dissection of the host cornea, a femtosecond laser-assisted large-diameter lamellar corneoscleral button, with varying thickness of 250-400 μm, was sutured to the recipient bed.

View Article and Find Full Text PDF

Wearable sensors are increasingly being used as biosensors for health monitoring. Current wearable devices are large, heavy, invasive, skin irritants, or not continuous. Miniaturization was chosen to address these issues, using a femtosecond laser-conversion technique to fabricate miniaturized laser-induced graphene (LIG) sensor arrays on and encapsulated within a polyimide substrate.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!