Objective: Inert surface of Polyetherketoneketone (PEKK) jeopardizes resin bonding. This study aimed to present a new adhesive protocol to improve PEKK bonding.

Methods: A total of 360 PEKK blocks were milled, polished (maximum roughness of 0.20 µm), and randomly assigned to groups. The new protocol was applied (n = 36) and compared to conventional treatments (no treatment; sandblasting (110-µm AlO and silica); no adhesive; Visiolink (Bredent); and PEKKbond (AnaxDent)) (n = 36). For the new protocol, the surface was blasted (110 µm AlO and 96% isopropyl alcohol at 60 psi), followed by 96% isopropyl alcohol washing, and air drying. PEKKbond was applied (dried for 3 min at 77 °C), followed by Visiolink (dried for 3 min at 60 °C); both light-cured for 3 min (800 mW/cm). Preopaque (GC Europe) and Opaque (AnaxDent) were applied and light-cured (5 min). Morphological topography was analyzed, and flowable gingiva-colored composite (AnaxGum, AnaxDent) was bonded. All specimens were aged for 24 h and thermocycled (5000 cycles, 5-55 °C). Shear bond strength (SBS) was measured (MPa) and data were analyzed by two-way ANOVA, Tukey, and Weibull moduli estimation (α = 0.05).

Results: The highest SBS values were found in the new protocol (p < 0.05), regardless of aging. Thermocycling reduced SBS (p < 0.05), while AlO and PEKKbond produced higher SBS values than silica and Visiolink, respectively (p < 0.05).

Significance: The new protocol strongly improves PEKK adhesiveness, and this can reflect in the longevity of prostheses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2023.10.001DOI Listing

Publication Analysis

Top Keywords

adhesive protocol
8
shear bond
8
bond strength
8
polyetherketoneketone pekk
8
96% isopropyl
8
isopropyl alcohol
8
dried 3 min
8
protocol improves
4
improves shear
4
strength polyetherketoneketone
4

Similar Publications

Introduction: This systematic review with network meta-analysis (NMA) analysed the current evidence on in vitro studies comparing trueness of fit, surface roughness, colour stability, surface wettability, water sorption, water solubility, and microbial adhesion between conventional and digital denture bases.

Methods: From inception until December 2023, a systematic search of published in-vitro studies from Scopus, PubMed, and the Cochrane Central Register of Controlled Studies was conducted. The protocol was registered in PROSPERO (CRD42024531416).

View Article and Find Full Text PDF

Evaluation of the Management Strategies for Adhesive Small-Bowel Obstruction.

J Surg Res

January 2025

Center for Injury Science, University of Alabama at Birmingham, Administration Bldg, Birmingham, Alabama. Electronic address:

Introduction: The management of adhesive small-bowel obstruction (aSBO) continues to have wide variation, with no one management strategy accepted as the optimal. The first objective was to evaluate the methods of management and the variations in the management of aSBO at our institution and evaluate the outcomes of those management strategies. The second objective was to compare our outcomes to those of a published study by which patients were managed using an institutional protocol for aSBO.

View Article and Find Full Text PDF

This research aimed to assess the shear bond strength (SBS) of metal brackets bonded to composite veneers using different surface preparations. One-hundred composite disks were divided into 10 different groups whereby each group combines a surface preparation (roughening or no roughening), etching agent (37% phosphoric or 9.5% hydrofluoric acid), adhesive protocol (self-etch or total-etch), and bonding agent (with or without G-Premio Bond).

View Article and Find Full Text PDF

Background: Nasopharyngeal stenosis (NPS) is an uncommon but significant complication that arise following tonsillectomy in adults, leading to manifestations including obstructive sleep apnea and dysphagia. This condition is often rare, underscoring the need for awareness and effective management strategies.

Case Presentation: We present a case involving a 48-year-old female who developed nasopharyngeal stenosis (NPS) 15 months after undergoing a tonsillectomy.

View Article and Find Full Text PDF

Artificial fish nests are common tools in fisheries management, providing spawning grounds to enhance the size and diversity of fish populations. This study aimed to explore the effects of deployment locations on the reproductive efficiency and preferences of fish with adhesive and demersal eggs using artificial nests. Floating artificial nests were deployed in three regions (upstream, midstream, and downstream) of a reservoir in Zhejiang, China, at locations with three topographical types: steep slope (reservoir shore, slopes > 60°), gentle slope (reservoir shore, slopes < 30°), and confluence (middle thread of channel).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!