A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Vancomycin and Gentamicin Removal with the HA380 Cartridge during Experimental Hemoadsorption. | LitMetric

Introduction: Hemoadsorption has emerged as an adjunctive therapy for sepsis, but its impact on antibiotic levels remains poorly defined. We conducted an in vivo experimental study to investigate the removal of vancomycin and gentamicin during hemoadsorption using the HA380 cartridge, a novel styrene-divinylbenzene copolymer cartridge.

Methods: Six surgically prepared sheep were administered 2 g of vancomycin and 400 mg of gentamicin over 30 min, followed by a continuous infusion of vancomycin (20 mg/h). Hemoadsorption was implemented with a styrene-divinylbenzene copolymer HA380 cartridge at a blood flow of 120 mL/min. The removal ratio, sorbent-based clearance, and the mass removal rate were calculated for each time point.

Results: The mean 10-min vancomycin removal ratio exceeded 90% and declined to 68.0% at 30 min; 52.8% at 60 min, and 28.0% by 4 h. Due to constant plasma flow, clearance varied proportionally with the removal ratio. Over 4 hours, the total mass removal was 556 mg (SD 106.3). For gentamicin, the mean 10-min removal ratio was 96.9% and the final ratio at 4 h remained 53.0%, with clearances changing proportionately. The total mass removal of gentamicin was 138 mg (SD 26.6) over 4 h. The sorbent-based clearance of vancomycin was significantly lower than that of gentamicin (Pgroup < 0.0001).

Conclusion: The novel HA380 sorbent cartridge appears safe and achieves significant vancomycin and gentamicin removal over a four-hour period. This information can be used by clinicians to guide their prescription and consider the additional dosing of at least an extra 25-35% amount in patients receiving HA380 hemoadsorption therapy during sepsis.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000534108DOI Listing

Publication Analysis

Top Keywords

removal ratio
16
vancomycin gentamicin
12
ha380 cartridge
12
mass removal
12
removal
10
gentamicin removal
8
therapy sepsis
8
styrene-divinylbenzene copolymer
8
sorbent-based clearance
8
total mass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!