Purpose: To investigate whether depth-gauge burs in veneer preparations influence preparation depth in a randomized, controlled, single-blinded trial and whether inexperienced operators can perform adequate veneer preparations.

Methods: Participants were 20 undergraduate dental students with no prior veneer preparation experience. The instruments used were the "Laminate Veneer System" (LVS), "Keramik-Veneers. de" (KVD), and a "Freehand" group (FH) for reference. All participants prepared three educational acrylic resin maxillae and three mandibular central incisors mounted in typodonts in patient simulators. The objectives were to achieve a preparation depth of 0.6 mm (tooth 11) and 0.4 mm (tooth 31). The sequences of the instruments used and prepared teeth were randomized. The measurements were performed using a laser triangulation coordinate-measuring machine. The data were stratified according to tooth location.

Results: The preparation depths of both depth-gauge-instrument-groups LVS and KVD achieved the objectives significantly better than did the instruments from the "Freehand" group (P < 0.001). The differences between the depth gauge groups were insignificant, although the maximum preparation depths were smaller in the KVD group. Regarding the prepared teeth, the preparation depths in the mandibular incisors were lower, and the differences were smaller.

Conclusions: The use of special depth-gauge burs for initial veneer preparation leads to significantly lower preparation depths than "Freehand" preparations. The tapered instruments resulted in a lower incidence of extreme preparation depths. The inexperienced operators performed veneer preparation remarkably well.

Download full-text PDF

Source
http://dx.doi.org/10.2186/jpr.JPR_D_22_00317DOI Listing

Publication Analysis

Top Keywords

preparation depths
20
veneer preparation
16
preparation
11
depth-gauge burs
8
preparation depth
8
inexperienced operators
8
"freehand" group
8
prepared teeth
8
veneer
7
instruments
5

Similar Publications

Middle cerebral artery (MCA) aneurysms remain excellent candidates for microsurgical treatment, despite proliferation of new endovascular tools. Nonetheless, patients desire less invasive options for permanent, durable treatment of their aneurysms; this is particularly the case for those presenting without subarachnoid hemorrhage, and those with multiple aneurysms that may require several surgical approaches. Keyhole craniotomies, when properly utilized in well-selected patients, allow for minimally invasive treatment of both ruptured and unruptured cerebral aneurysms, including those harboring bilateral aneurysms which may be treated from a single approach.

View Article and Find Full Text PDF

The quantitative characterization of the structure of biomineral surfaces is needed for guiding regenerative strategies. Current techniques are compromised by a requirement for extensive sample preparation, limited length-scales, or the inability to repeatedly measure the same surface over time and monitor structural changes. We aim to address these deficiencies by developing Calcium (Ca) K-edge Polarisation Induced Contrast X-ray Fluorescence (PIC-XRF) to quantify hydroxyapatite (HAp) crystallite structural arrangements in high and low textured surfaces.

View Article and Find Full Text PDF

Patient-centred care and technical challenges during polytrauma imaging - Experiences from radiography students.

Radiography (Lond)

January 2025

Department of Radiography, School of Allied Health Sciences, Faculty of Health Sciences and Veterinary Medicine, University of Namibia, P.O Box 13301, Windhoek, Namibia. Electronic address:

Introduction: Patient-centred care (PCC) is essential in radiography for polytrauma patients emphasising empathy, clear communication, and patient well-being. Polytrauma patients require tailored imaging approaches, often involving multiple modalities. Managing and handling these patients during imaging are key components of radiography training to develop the necessary competencies.

View Article and Find Full Text PDF

Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control.

View Article and Find Full Text PDF

In vitro antischistosomal activity of Artemisia species.

Acta Trop

January 2025

Centre of Excellence for Pharmaceutical Sciences (Pharmacen(TM)), North-West University, Private Bag X6001, Potchefstroom 2520, South Africa. Electronic address:

Praziquantel is currently the only effective treatment for schistosomiasis, but several limitations underscore the need for new therapeutic agents. Recent promising in vitro results with Artemisia species and the success of A. annua and its active compound artemisinin in treating parasitic infections warrant the need for further studies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!