Due to the intrinsic safety and cost effectiveness, aqueous Zn-ion batteries (AZIBs) are considered a promising candidate for future energy storage systems. However, the widespread implementation of AZIBs faces significant obstacles due to various undesirable side reactions, including hydrogen evolution reaction (HER), corrosion, and uncontrolled dendrite growth at the anodes. Here, 4-hydroxybenzoic acid sodium salt (PHB) is employed in the ZnSO electrolyte to enable highly-reversible zinc anodes. PHB has a greater tendency to bind with the Zn surface, resulting in increased steric effects within the electrolyte. As a result, it hinders the direct interaction between anode and water while facilitating the uniform plating of Zn . Zn/Zn batteries with PHB additives realized more than 1600 h stable cycling life under 1 mA cm and 1 mAh cm . Moreover, Zn/Cu batteries with PHB additives achieved a reversible plating/stripping process for over 500 cycles with high average CE of 98.6 %. In addition, the assembled Zn/NH V O batteries with PHB additive yielded 80.5 mAh g after 1000 cycles at 10 A g . The inexpensive and effective application of PHB as an electrolyte additive has the potential to significantly enhance the stability and dependability of ZIBs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/cssc.202301331 | DOI Listing |
ChemSusChem
February 2024
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, 28 West Xianning Road, Xi'an, 710049, China.
Due to the intrinsic safety and cost effectiveness, aqueous Zn-ion batteries (AZIBs) are considered a promising candidate for future energy storage systems. However, the widespread implementation of AZIBs faces significant obstacles due to various undesirable side reactions, including hydrogen evolution reaction (HER), corrosion, and uncontrolled dendrite growth at the anodes. Here, 4-hydroxybenzoic acid sodium salt (PHB) is employed in the ZnSO electrolyte to enable highly-reversible zinc anodes.
View Article and Find Full Text PDFJ Plast Reconstr Aesthet Surg
November 2009
Department of Hand & Plastic Surgery, Umeå University SE-901 87 Umeå, Sweden.
Peripheral nerve injures are common and often result in impaired functional recovery. The majority of injuries involve the arm and/or the hand. The traditional treatment for peripheral nerve injuries is repair by using microsurgical techniques, either by primary nerve suture or nerve graft, but research to find more successful methods that could improve recovery is ongoing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!