A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of Positive/Inconclusive Xpert Xpress SARS-CoV-2 with the Standard M nCoV Real-Time Detection. | LitMetric

Background: COVID-19, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), can be diagnosed using rapid real-time PCR, real-time reverse transcription PCR (rRT-PCR), or rapid antigen testing. Among these, rRT-PCR is considered the gold standard assay. The Xpert Xpress SARS-CoV-2 assay is a rapid real-time PCR test, approved by the Korean Disease Control and Prevention Agency in 2020. The overall concordance and positive concordance rates of the Xpert assay with the STANDARD M nCoV Real-Time Detection kit were determined.

Methods: All samples with positive or inconclusive Xpert test results from July 2021 to February 2023 that underwent confirmatory testing using the reference rRT-PCR assay were included in the analysis.

Results: Samples from 224 patients (93 men and 131 women) with a median age of 59 years (range 15 - 90 years) were included. Of 212 samples that tested positive using Xpert, 112 (52.8%) were true positves and 100 (47.2%) were false positives on rRT-PCR testing. The overall concordance and positive concordance rates were 52.8% (112/212) and 54.5% (112/224), respectively. In the Xpert positive group, the samples had a lower Ct value for the E gene than the N2 gene. The Ct values for the E and N2 genes were significantly lower in the positive group than in the inconclusive group.

Conclusions: Positive or inconclusive Xpert results should be confirmed by the gold standard rRT-PCR for early control of this disease. Furthermore, Korea's policy should be reconsidered given the high false-positive rate of the rapid real-time PCR Xpert Xpress SARS-CoV-2 assay.

Download full-text PDF

Source
http://dx.doi.org/10.7754/Clin.Lab.2023.230546DOI Listing

Publication Analysis

Top Keywords

xpert xpress
12
xpress sars-cov-2
12
rapid real-time
12
real-time pcr
12
xpert
8
standard ncov
8
ncov real-time
8
real-time detection
8
gold standard
8
sars-cov-2 assay
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!