Beneficial effects of upgrading to His-Purkinje system pacing in patients with pacing-induced cardiomyopathy: a systematic review and meta-analysis.

PeerJ

Geriatric Diseases Institute of Chengdu/Cancer Prevention and Treatment Institute of Chengdu, Department of Cardiology, Chengdu Fifth People's Hospital (The Second Clinical Medical College, Affiliated Fifth People's Hospital of Chengdu University of Traditional Chinese Medicine), Chengdu, China.

Published: October 2023

Background: The purpose of this study was to evaluate the effectiveness of His-Purkinje system pacing (HPSP) in the management of patients with pace-induced cardiomyopathy (PICM).

Methods: PubMed, Embase, Web of Science, and the Cochrane Library were searched comprehensively to collect related studies published from the inception of databases to June 1, 2022. R 4.04 software, including the Metafor package, matrix package, and the Meta package, was utilized to conduct the singe-arm meta-analysis. The methodology index for non-randomized studies (MINORS) was used to assess the methodological quality of the included studies.

Results: A total of seven studies were included, involving 164 PICM patients. The meta-analysis showed that HPSP ameliorated the left ventricular ejection fraction (LVEF) by 13.41% (95% CI [11.21-15.61]), improved the New York Heart Association (NYHA) classification by 1.02 (95% CI [-1.41 to -0.63]), and shortened the QRS duration (QRSd) by 60.85 ms (95% CI [-63.94 to -57.75]), resulting in improved cardiac functions in PICM patients. Besides, HPSP reversed the ventricular remodeling, with a 32.46 ml (95% CI [-53.18 to -11.75]) decrease in left ventricular end systolic volume (LVESV) and a 5.93 mm (95% CI [-7.68 to -4.19]) decrease in left ventricular end-diastolic dimension (LVEDD). HPSP also showed stable electrical parameters of pacemakers, with a 0.07 V (95% CI [0.01-0.13]) increase in pacing threshold, a 0.02 mV (95% CI [-0.85 to 0.90]) increase in sensed R-wave amplitude, and a 31.12 Ω reduction in impedance (95% CI [-69.62 to 7.39]). Compared with LBBP, HBP improved LVEF by 13.28% (95% CI [-11.64 to 14.92]) 14.43% (95% CI [-13.01 to 15.85]), ameliorated NHYA classification by 1.18 (95% CI [-1.97 to -0.39]) 0.95 (95% CI [-1.33 to -0.58]), shortened QRSd by 63.16 ms (95% CI [-67.00 to -59.32]) 57.98 ms (95% CI [-62.52 to -53.25]), and decreased LVEDD by 4.12 mm (95% CI [-5.79 to -2.45]) 6.26 mm (95% CI [-62.52 to -53.25]). The electrical parameters of the pacemaker were stable in both groups.

Conclusions: This meta-analysis showed that HPSP could significantly improve cardiac function, promote reverse remodeling, and provide stable electrical parameters of pacemakers for PICM patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10576494PMC
http://dx.doi.org/10.7717/peerj.16268DOI Listing

Publication Analysis

Top Keywords

95%
16
picm patients
12
left ventricular
12
electrical parameters
12
his-purkinje system
8
system pacing
8
meta-analysis hpsp
8
decrease left
8
stable electrical
8
parameters pacemakers
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!