A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A retrospective audit of young adults who received permanent pacemakers at a teaching hospital in the Western Cape, South Africa. | LitMetric

A retrospective audit of young adults who received permanent pacemakers at a teaching hospital in the Western Cape, South Africa.

Front Cardiovasc Med

Division of Cardiology, Department of Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University, Tygerberg Hospital, Cape Town, South Africa.

Published: September 2023

Introduction: While most pacemaker implantations occur in older individuals, younger patients also receive pacemakers. In these, degenerative conduction system disease is less likely to be the cause of atrioventricular block (AVB), with other diseases being more common. There is, however, a paucity of data on this group as well as on younger pacemaker recipients that have undergone pacemaker implantation for reasons other than AVB. The aim of this study was to perform an audit of young adult permanent pacemaker recipients.

Method: This was a retrospective record review, conducted in the Division of Cardiology at Tygerberg Hospital, Cape Town, South Africa. We included 169 adult patients between the ages of 18 and 60, who received permanent pacemakers between 2010 and 2020. A subgroup analysis of patients 55 years and younger was also performed.

Results: Third degree AVB was the most common indication for pacemaker implantation ( = 115; 68%), followed by high degree AVB ( = 23; 13.6%) and sick sinus syndrome (SSS;  = 14; 8.3%). A specific underlying cause for conduction system abnormalities was found in only 25.4% of patients ( = 43), with most of them being 55 years or younger ( = 32; 30.8% of patients ≤ 55 years). Specific causes that were identified included prosthetic valve implantation and/or valve repair ( = 14; 8.3%), myocardial infarction ( = 6; 3.6%), cardiac sarcoidosis ( = 5; 3.0%), coronary artery bypass grafting ( = 3; 1.8%), cardiomyopathy ( = 2; 1.2%), muscular dystrophy ( = 2; 1.2%), congenital heart disease (ventricular septal defect; atrioventricular septal defect; Tetralogy of Fallot; bicuspid aortic valve;  = 6; 3.6%), acute myocarditis ( = 1; 0.6%), atrial myxoma removal ( = 1; 0.6%), planned AV node ablation ( = 2; 1.2%), and following a previous stab in the chest ( = 1; 0.6%).

Conclusion: Given that the mean age of our study population was high, the low number of identified underlying causes in the whole cohort (≤60 years) may reflect some AVB due to age related degeneration of the conductions system in the patients 56 to 60 years age, but also raises the possibility that these patients may be less likely to be extensively investigated for an underlying cause than those ≤55 years, where diseases such as sarcoidosis were more readily confirmed. As access to advanced diagnostic tools improves, the percentage of young pacemaker recipients with an underlying cause identified may increase.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10570724PMC
http://dx.doi.org/10.3389/fcvm.2023.1235197DOI Listing

Publication Analysis

Top Keywords

 = 2 12%
12
audit young
8
received permanent
8
permanent pacemakers
8
south africa
8
conduction system
8
pacemaker recipients
8
pacemaker implantation
8
patients years
8
years younger
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!