Transcatheter pulmonary valve replacement (TPVR) is commonly performed in patients with congenital heart disease as a safe alternative to replacement via open heart surgery. Intracardiac echocardiography (ICE) is a useful technique for evaluating multiple structures that are difficult to assess by other echocardiographic techniques, particularly the pulmonary valve. To our knowledge, the use of three-dimensional (3D) ICE catheters to evaluate prosthetic valves after TPVR has not been reported. Three-dimensional ICE catheters offer a comprehensive evaluation of transcatheter-deployed pulmonary valves through 3D, 3D color, xPlane, and multiplane reconstruction. The aim of this study is to demonstrate the feasibility of using 3D ICE catheters, outline their role in evaluating post-TPVR deployment success and complications, consider their additive value to two-dimensional ICE, and present our institutional experience with it in 50 cases of TPVR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.echo.2023.10.006 | DOI Listing |
JACC Clin Electrophysiol
January 2025
Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas, USA; Interventional Electrophysiology, Scripps Clinic, San Diego, California, USA; Metro Health Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA; Department of Biomedicine and Prevention, Division of Cardiology, University of Tor Vergata, Rome, Italy. Electronic address:
Background: Earlier studies have documented the risk for sinoatrial node injury and phrenic nerve paralysis as complications following radiofrequency catheter ablation for electrical isolation of the superior vena cava (SVCI).
Objectives: The aim of this study was to assess the safety and feasibility of SVCI in patients with atrial fibrillation undergoing pulsed field ablation (PFA) METHODS: Six hundred sixteen consecutive patients undergoing PFA for pulmonary vein isolation plus SVCI were included in this multicenter analysis. Superior vena cava (SVC) ablation was performed under the continuous guidance of intracardiac echocardiography.
Sci Rep
January 2025
Cardiovascular Research Institute, General Hospital of Northern Theater Command, No. 83 Wenhua Road, Shenhe District, Shenyang, 110016, Liaoning, China.
Using transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) to investigate the occurrence and related causes of iatrogenic atrial septal defect (iASD) after catheter ablation combined with left atrial appendage closure (LAAC) for atrial fibrillation (AF) and its impact on the right heart system. We retrospectively analyzed 330 patients that underwent combined procedure of catheter ablation for AF and LAAC at General Hospital of Northern Theater Command from January 2018 to March 2022. These patients were divided into iASD group and non-iASD group according to whether there was persistent iASD shown on TEE at 3 months after procedure.
View Article and Find Full Text PDFZhonghua Xin Xue Guan Bing Za Zhi
January 2025
Department of Cardiology, General Hospital of Northern Theater Command, National Key Laboratory of Frigid Zone Cardiovascular Diseases, Shenyang110016, China.
To assess the efficacy and safety of "one-stop" procedures combining radiofrequency catheter ablation and left atrial appendage closure by guidance of intracardiac echocardiography(ICE) in elderly patients with atrial fibrillation. A retrospective cohort study was conducted on patients who underwent ICE-guided "one-stop" procedures at the Department of Cardiology, General Hospital of Northern Theater Command between December 2020 and January 2023. Patients were divided into elderly group (age≥60 years old) and non-elderly group (age 18-59 years old).
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
December 2024
Division of Cardiovascular Medicine, Cardiac Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Introduction: Intracardiac echocardiography (ICE) is an essential imaging modality for electrophysiology procedures, allowing intraprocedural monitoring, real-time catheter manipulation guidance, and visualization of complex anatomic structures. Four-dimentional (4D) ICE is the next stage in the evolution of the technology, permitting 360° rotation of the imaging plane, simultaneous multiplanar imaging, and volumetric acquisition, similar to transesophageal echocardiography (TEE). In this study, we report our experience with a novel 4D ICE catheter (NuVision, Biosense Webster) in structural electrophysiology procedures and difficult ventricular ablations in a swine preclinical model.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Cardiology, West China Hospital of Sichuan University, 37 Guoxue Alley, Wuhou District, Chengdu, 610041, Sichuan, China.
Intracardiac echocardiography (ICE) has been used to guide radio-frequency catheter ablation (RFCA) for better catheter navigation and less radiation exposure in treating atrial fibrillation (AF). This retrospective cohort study enrolled 227 AF patients undergoing ICE- or traditional fluoroscopy (TF)-guided RFCA for AF in a tertiary hospital. ICE was used more often in patients with atrial tachycardia [odds ratio (OR) 3.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!