Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In the field of oil refining, the presence of excessive residual phosphorus in crude oil can significantly impact its quality, thereby emphasizing the necessity for compact and convenient testing equipment. This study primarily focuses on developing of self-powered biosensor (SPB) using immobilizing Choline Oxidase with a photoactive ternary nanocomposite complex (CHOx-BiOI-rGO-FeO NPs-ITO) as the anode and utilizing a Pt electrode as the cathode. The successful preparation of the ternary composite photoelectrode for the anode was confirmed through a range of characterization techniques, including X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), Transmission electron microscopy (TEM), Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), N absorption/desorption, Dynamic light scattering (DLS), and Ultraviolet-visible diffuse reflection spectrometer (UV-vis DRS). The electrochemical and photoelectrochemical properties were assessed using an electrochemical workstation, revealing a significant enhancement photoelectrical responsiveness attributed to the formation of heterojunction structures. The SPB exhibited a remarkable linear relationship between the instantaneous photocurrent and phosphatidylcholine (PC) concentration, with a regression equation of I (μA) = 39.62071C (mM) + 3.47271. The linear range covered a concentration range of 0.01-10 mM, and the detection limit (S/N = 3) was determined to be 0.008 mM. It demonstrated excellent reproducibility and storage stability, positioning it a promising alternative to High-performance liquid chromatography (HPLC) for accurate quantification of PC content in rhodotorula glutinis oil. The standard recovery PC content ranged from 98.48% to 103.53%, with a relative standard deviation (RSD) ranging from 1.4% to 2.4%. This research presents a convenient and precise detection device that has the potential to address the issue of lagging detection in the oil refining process.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2023.115751 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!