A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Femtosecond laser-induced fluorescence for rapid monitoring of cardiac troponin 1 as a cardiovascular disease biomarker. | LitMetric

Femtosecond laser-induced fluorescence for rapid monitoring of cardiac troponin 1 as a cardiovascular disease biomarker.

Spectrochim Acta A Mol Biomol Spectrosc

Laser Institute for Research and Applications LIRA, Beni-Suef University, Beni-Suef 62511, Egypt. Electronic address:

Published: January 2024

Medical diagnosis usually requires blood analysis of various biomarkers which are essential for disease detection and health status monitoring. Cardiac troponin 1 (cTn1) is a protein member of the cardiac troponin complex used for the diagnosis of several pathologies associated with cardiomyocyte necrosis. Laser-induced fluorescence (LIF) is a technique with high sensitivity and specificity, and it is one of the most significant developments used as an analytical tool for qualitative and quantitative analysis. The current study investigated the potential application of femtosecond LIF as a novel detection technique for rapid monitoring of cTn1 in clinical analysis. In the present study, the cTn1 (8 ng/ml) was excited over wavelengths ranging from 350 to 400 nm, and the LIF spectra were recorded. The results demonstrated that the maximum fluorescence intensity was observed at an excitation wavelength of 350 nm, with an emitted fluorescence peak centeredat 494 nm. At an excitation wavelength of 350 nm, different concentrations of cTn1 have been investigated and LIF spectra were obtained. The results revealed that the fluorescence peak intensity is concentration-dependent and increases linearly with increasing cTn1 concentration. These findings show that femtosecond LIF presents a unique, highly selective, precise, and direct approach to monitoring cTn1.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2023.123491DOI Listing

Publication Analysis

Top Keywords

cardiac troponin
12
laser-induced fluorescence
8
rapid monitoring
8
monitoring cardiac
8
femtosecond lif
8
monitoring ctn1
8
lif spectra
8
excitation wavelength
8
wavelength 350 nm
8
fluorescence peak
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!