This study aims to evaluate the lifespan of Ti-Ag dry electrodes prepared using flexible polytetrafluoroethylene (PTFE) substrates. Following previous studies, the electrodes were designed to be integrated into wearables for remote electromyography (EMG) monitoring and electrical stimulation (FES) therapy. Four types of Ti-Ag electrodes were prepared by DC magnetron sputtering, using a pure-Ti target doped with a growing number of Ag pellets. After extensive characterization of their chemical composition and (micro)structural evolution, the Ti-Ag electrodes were immersed in an artificial sweat solution (standard ISO-3160-2) at 37 °C with constant stirring. Results revealed that all the Ti-Ag electrodes maintained their integrity and functionality for 24 h. Although there was a notable increase in electrical resistivity beyond this timeframe, the acquisition and transmission of (bio)signals remained viable for electrodes with Ag/Ti ratios below 0.23. However, electrodes with higher Ag content (Ag/Ti = 0.31) became insulators after 7 days of immersion due to excessive Ag release into the sweat solution. This study concludes that higher Ag/Ti atomic ratios result in heightened corrosion processes on the electrode's surface, consequently diminishing their lifespan despite the advantages of incorporating Ag into their composition. This research highlights the critical importance of evaluating electrode longevity, especially in remote biomedical applications like smart wearables, where electrode performance over time is crucial for reliable and sustained monitoring and stimulation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10575150PMC
http://dx.doi.org/10.3390/s23198321DOI Listing

Publication Analysis

Top Keywords

ti-ag electrodes
12
ti-ag dry
8
electrodes
8
dry electrodes
8
remote biomedical
8
biomedical applications
8
electrodes prepared
8
sweat solution
8
ti-ag
5
enhancing longevity
4

Similar Publications

Enhanced response of WO thin film through Ag loading towards room temperature hydrogen gas sensor.

Chemosphere

April 2024

Department of Physics, Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram, Off Vandalur-Kelambakkam Road, Chennai, 600127, India. Electronic address:

This study investigates the enhancement of hydrogen gas-sensing performance by introducing silver (Ag) nanoparticles onto tungsten trioxide (WO) thin films. Herein, the WO thin films are deposited onto SiO/Si substrates using a sputtering technique and Ag nanoparticles are loaded onto the WO surface through a spin coating technique. To evaluate the sensing performance of a hydrogen gas, interdigitated titanium (Ti) electrodes are deposited onto the Ag:WO layer.

View Article and Find Full Text PDF

Microporous Ag/AgCl on a Titanium Scaffold for Use in Capillary Reference Electrodes.

Anal Chem

February 2024

Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States.

AgCl-coated silver fabricated with the thermal-electrolytic method can be used to prepare more reproducible reference electrodes than Ag/AgCl prepared with alternative methods such as electrolytic and chemical AgCl deposition or thermal fabrication. However, thermal-electrolytic fabrication requires a scaffold material upon which to build the layers upon. Platinum and rhodium have been used for this purpose as they are mechanically strong and chemically inert, but their cost is prohibitive for wider application.

View Article and Find Full Text PDF

This study aims to evaluate the lifespan of Ti-Ag dry electrodes prepared using flexible polytetrafluoroethylene (PTFE) substrates. Following previous studies, the electrodes were designed to be integrated into wearables for remote electromyography (EMG) monitoring and electrical stimulation (FES) therapy. Four types of Ti-Ag electrodes were prepared by DC magnetron sputtering, using a pure-Ti target doped with a growing number of Ag pellets.

View Article and Find Full Text PDF

Room temperature giant magnetoresistance in half-metallic CrC based two-dimensional tunnel junctions.

Nanoscale

July 2022

Nano-Scale Device Research Laboratory, Department of Electronic Systems Engineering, Indian Institute of Science (IISc), Bangalore, Bangalore 560012, India.

Two-dimensional (2D) magnetic materials inherit enormous potential to revolutionize next-generation spintronic technology. The majority of prior investigations using 2D ferromagnet-based tunnel junctions have shown encouraging tunnel magnetoresistance (TMR) at low temperatures. Using first-principles-based calculations, here we investigate the magnetic properties of commercially available CrC crystals at their monolayer limit and reveal their half metallicity properties far beyond room temperature.

View Article and Find Full Text PDF

Graphene-Based Contacts for Optoelectronic Devices.

Micromachines (Basel)

October 2020

CIEMAT, Departamento de Energía, Unidad de Energía Solar Fotovoltaica, Avda. Complutense 40, 28040 Madrid, Spain.

Hybrid transparent contacts based on combinations of a transparent conductive oxide and a few graphene monolayers were developed in order to evaluate their optical and electrical performance with the main aim to use them as front contacts in optoelectronic devices. The assessment of the most suitable strategies for their fabrication was performed by testing different protocols addressing such issues as the protection of the device structure underneath, the limitation of sample temperature during the graphene-monolayer transfer process and the determination of the most suitable stacking structure. Suitable metal ohmic electrodes were also evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!