A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Impact of Milled Wood Waste Bottom Ash (WWBA) on the Properties of Conventional Concrete and Cement Hydration. | LitMetric

Wood waste bottom ash (WWBA) is a waste generated in power plants during the burning of forest residues to produce energy and heat. In 2019, approximately 19,800 tons of WWBA was generated only in Lithuania. WWBA is rarely recycled or reused and is mostly landfilled, which is both costly for the industry and unsustainable. This study presents a sustainable solution to replace a part of cement with WWBA at 3%, 6%, 9%, and 12% by weight. Problems are also associated with the use of this material, as WWBA could have a relatively large surface area and a high water demand. For the evaluation of the possibilities of WWBA use for cementitious materials, the calorimetry test for the cement paste as well as X-ray diffraction (XRD), thermography (TG, DTG), and porosity (MIP) for hardened cement paste with the results of physical and mechanical properties, and the freeze-thaw resistance of the concrete was measured and compared. It was found that WWBA with a large quantity of CO could be used as a microfiller with weak pozzolanic properties in the manufacture of cementitious materials. As a result, concrete containing 6% WWBA used to substitute cement has higher density, compressive strength at 28 days, and ultrasonic pulse velocity values. In terms of durability, it was verified that concrete modified with 3%, 6%, 9%, and 12% WWBA had a freeze-thaw resistance level of F150. The results show that the use of WWBA to replace cement is a valuable sustainable option for the production of conventional concrete and has a positive effect on durability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573931PMC
http://dx.doi.org/10.3390/ma16196498DOI Listing

Publication Analysis

Top Keywords

wwba
11
wood waste
8
waste bottom
8
bottom ash
8
ash wwba
8
conventional concrete
8
replace cement
8
wwba large
8
cementitious materials
8
cement paste
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!