Seamlessly integrated textile electrodes and conductive routing in a garment for electrostimulation: design, manufacturing and evaluation.

Sci Rep

Textile Materials Technology, Department of Textile Technology, Faculty of Textiles, Engineering and Business Swedish School of Textiles, University of Borås, Borås, Sweden.

Published: October 2023

Electro-stimulation to alleviate spasticity, pain and to increase mobility has been used successfully for years. Usually, gelled electrodes are used for this. In a garment intended for repeated use such electrodes must be replaced. The Mollii-suit by the company Inerventions utilises dry conductive rubber electrodes. The electrodes work satisfactory, but the garment is cumbersome to fit on the body. In this paper we show that knitted dry electrodes can be used instead. The knitted electrodes present a lower friction against the skin and a garment is easily fitted to the body. The fabric is stretchable and provides a tight fit to the body ensuring electrical contact. We present three candidate textrodes and show how we choose the one with most favourable features for producing the garment. We validate the performance of the garment by measuring three electrical parameters: rise time (10-90%) of the applied voltage, net injected charge and the low frequency value of the skin-electrode impedance. It is concluded that the use of flat knitting intarsia technique can produce a garment with seamlessly integrated conductive leads and electrodes and that this garment delivers energy to the body as targeted and is beneficial from manufacturing and comfort perspectives.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10575854PMC
http://dx.doi.org/10.1038/s41598-023-44622-5DOI Listing

Publication Analysis

Top Keywords

seamlessly integrated
8
electrodes
8
garment
8
electrodes garment
8
fit body
8
integrated textile
4
textile electrodes
4
electrodes conductive
4
conductive routing
4
routing garment
4

Similar Publications

Feedback plays a crucial role in the growth and development of trainees, particularly when addressing areas needing improvement. However, faculty members often struggle to deliver constructive feedback, particularly when discussing underperformance. A key obstacle is the lack of comfort many faculty experience in providing feedback that fosters growth.

View Article and Find Full Text PDF

Quotient Complex (QC)-Based Machine Learning for 2D Hybrid Perovskite Design.

J Chem Inf Model

January 2025

Division of Physics & Applied Physics, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371, Singapore.

With remarkable stability and exceptional optoelectronic properties, two-dimensional (2D) halide layered perovskites hold immense promise for revolutionizing photovoltaic technology. Effective data representations are key to the success of all learning models. Currently, the lack of comprehensive and accurate material representations has hindered AI-based design and discovery of 2D perovskites, limiting their potential for advanced photovoltaic applications.

View Article and Find Full Text PDF

Background: Producing speech is a cognitively complex task and can be collected through devices such as handheld recorders, tablets, and smartphones. Digital voice data can also capture information at a granular millisecond-level precision and serve as a widespread tool to collect cognitively relevant data in almost any diverse real-world environments. Digital voice recordings of spoken responses to neuropsychological test questions have been collected through the Framingham Heart Study (FHS) since 2005.

View Article and Find Full Text PDF

Background: The outcomes of extensive Genome-Wide Association Study (GWAS) data in Polygenic Risk Score (PRS) studies exhibit varying odds ratios (ORs), ranging from 1.13 (Bellenguez) to 1.34 (Kunkle).

View Article and Find Full Text PDF

Effectiveness of Using a Digital Wearable Plantar Pressure Device to Detect Muscle Fatigue: Within-Subject, Repeated Measures Experimental Design.

JMIR Hum Factors

January 2025

Department of Biomedical Engineering, Chung Yuan Christian University, No. 200, Zhongbei Road, Zhongli District, Toayuan City, 32023, Taiwan, 886 32564507.

Background: Muscle fatigue, characterized by reduced force generation during repetitive contractions, impacts older adults doing daily activities and athletes during sports activities. While various sensors detect muscle fatigue via muscle activity, biochemical markers, and kinematic parameters, a real-time wearable solution with high usability remains limited. Plantar pressure monitoring detects muscle fatigue through foot loading changes, seamlessly integrating into footwear to improve the usability and compliance for home-based monitoring.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!