We developed a 3D convolutional neural network (CNN)-based automatic kidney segmentation method for patients with chronic kidney disease (CKD) using MRI Dixon-based T1-weighted in-phase (IP)/opposed-phase (OP)/water-only (WO) images. The dataset comprised 100 participants with renal dysfunction (RD; eGFR < 45 mL/min/1.73 m) and 70 without (non-RD; eGFR ≥ 45 mL/min/1.73 m). The model was applied to the right, left, and both kidneys; it was first evaluated on the non-RD group data and subsequently on the combined data of the RD and non-RD groups. For bilateral kidney segmentation of the non-RD group, the best performance was obtained when using IP image, with a Dice score of 0.902 ± 0.034, average surface distance of 1.46 ± 0.75 mm, and a difference of - 27 ± 21 mL between ground-truth and automatically computed volume. Slightly worse results were obtained for the combined data of the RD and non-RD groups and for unilateral kidney segmentation, particularly when segmenting the right kidney from the OP images. Our 3D CNN-assisted automatic segmentation tools can be utilized in future studies on total kidney volume measurements and various image analyses of a large number of patients with CKD.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10575938 | PMC |
http://dx.doi.org/10.1038/s41598-023-44539-z | DOI Listing |