Introduction: Prescribers have the medicolegal responsibility to ensure a sufficiently reliable system is in place to securely monitor the process of efficiently communicating laboratory results. With added complexity of technologies such as electronic medical record systems, few studies address the monitoring, verification and improvement of test results follow-up especially within a teaching facility including resident prescribers.

Method: The main goal of this quality improvement project was to ensure safety of care through reliable test results follow-up and adapting processes to available technology by (1) implementing an improved, more reliable and efficient system for tracking test results in the setting; and (2) increasing perceived reliability of test results monitoring system of prescribers in the clinical setting. Through three Plan-Do-Study-Act cycles, changes were implemented: (1) family medicine residents recognised as prescribers; (2) connection of prescribers to regional techno-centre; and (3) computer protocol eliminating duplicates. Patients and clinical staff completed surveys (satisfaction, perceived safety and reliability).

Analysis: Quantitative and qualitative data were collected, reported incidents, requested prescriptions and received results and time spent communicating normal results. Immediate feedback from prescribers and staff members was considered to improve the process. Microsoft Excel software was used to calculate mean and SD of error rate. Shewhart chart rules were used to determine special cause of change and sustainability.

Results: Implemented changes led to decrease in mean error rate (from 6.1% to 1.9%), variation of range (from 2.7-12.1% to 0-4.8%) and SD (from 2.1% to 1.2%). The improvement is sustained over 24 months after the last cycle. 100% of the 30 patients surveyed were satisfied with the changes implemented. Prescribers (75% response rate) including residents (15.8% response rate) perceived the improved system to be safer, more reliable and efficient.

Conclusion: Implemented changes improved reliability, efficiency and perceived safety of the test results monitoring system while ensuring patient satisfaction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10582889PMC
http://dx.doi.org/10.1136/bmjoq-2023-002291DOI Listing

Publication Analysis

Top Keywords

safer reliable
8
reliable system
8
family medicine
8
quality improvement
8
test follow-up
8
test monitoring
8
monitoring system
8
changes implemented
8
perceived safety
8
error rate
8

Similar Publications

Background: Transvenous pacemakers (TVP) and leadless pacemakers (LP) are two reliable permanent modalities for the treatment of heart rhythm disorders. Several observational studies explored the safety and efficacy of the two devices. The aim of this meta-analysis study is to present a comparative analysis of the safety of leadless versus transvenous pacemakers.

View Article and Find Full Text PDF

Background: There is a lack of high-quality evidence to support the recommendation of an instrument to screen emergency department patients for their risk for violence.

Objective: To demonstrate the content and predictive validity and reliability of the novel Risk for Violence Screening Tool to identify patients at risk for violence.

Design And Setting: This retrospective risk screening study was conducted at a 100-bed emergency department in an urban, academic, safety net trauma center in Southern California.

View Article and Find Full Text PDF

: This study compares system-reported organ doses (ODs) to manually calculated mean glandular doses (MGDs) in mammography across multiple centers and manufacturers in Dubai. : A retrospective study of 2754 anonymized mammograms from six clinics in Dubai were randomly retrieved from a central dose survey database. Organ doses were documented along with other dosimetry information like kVp, mAs, filter, target, compression force, and breast thickness.

View Article and Find Full Text PDF

Background: This study aimed to gather information about parental practices, knowledge, and attitudes regarding infant sleep habits and environments, among families who practice non-recommended sleep practices.

Methods: We conducted one-on-one phone interviews with parents who had practiced non-recommended sleep methods with their infant and had or had not experienced an undesirable sleep event such as a fall. Interviews were recorded and coded with MAXQDA software.

View Article and Find Full Text PDF

Public transportation systems play a vital role in modern cities, but they face growing security challenges, particularly related to incidents of violence. Detecting and responding to violence in real time is crucial for ensuring passenger safety and the smooth operation of these transport networks. To address this issue, we propose an advanced artificial intelligence (AI) solution for identifying unsafe behaviours in public transport.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!