AI Article Synopsis

  • This study introduces a new active optical heterodyne detection system that improves phase compensation in coherent detection systems using advanced technology.
  • It features a high-speed camera array and utilizes a heuristic search algorithm (HSA) to efficiently solve complex optimization problems, leading to faster performance.
  • Experimental results show that this system can significantly boost the detection signal's amplitude, making it promising for spotting weak targets and encouraging further exploration in this research area.

Article Abstract

This study proposes an innovative active optical heterodyne detection system to address the limitations of existing swarm intelligence algorithms in resolving phase compensation issues within coherent detection systems. The design incorporates a high-speed camera array detector, offering improved practicality and a simplified structure. Employing a heuristic search algorithm (HSA) transforms the high-dimensional problem into multiple one-dimensional optimization problems, significantly enhancing algorithmic running speed. The HSA maintains excellent performance even with increased array elements, allowing for real-time phase correction in large arrays. Experimental results using shot peening comparison samples reveal a substantial amplification of the heterodyne signal spectrum amplitude peak, approximately 60 times greater than the original signal. This innovative approach holds great potential for active optical heterodyne detection of dim targets, paving the way for further research in the field.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.500332DOI Listing

Publication Analysis

Top Keywords

optical heterodyne
12
heterodyne detection
12
detection system
8
high-speed camera
8
phase compensation
8
active optical
8
detection
4
system high-speed
4
camera based
4
based hsa
4

Similar Publications

An ultra-narrow-linewidth laser is a core device in fields such as optical atomic clocks, quantum communications, and microwave photonic oscillators. This paper reports an ultra-narrow-linewidth self-injection locked semiconductor laser, which is realized through optical feedback from a high-Q (258 million) Fabry-Perot (FP) cavity constructed with three mirrors, generating an output power of 12 mW. Employing a delay self-heterodyne method based on a signal source analyzer, the phase noise of the laser is -129 dBc/Hz at 100 kHz offset frequency, with an intrinsic linewidth of 3 mHz.

View Article and Find Full Text PDF

Approaching the standard quantum limit of a Rydberg-atom microwave electrometer.

Sci Adv

December 2024

Key Laboratory of Atomic and Subatomic Structure and Quantum Control (Ministry of Education), Guangdong Basic Research Center of Excellence for Structure and Fundamental Interactions of Matter, School of Physics, South China Normal University, Guangzhou 510006, China.

The development of a microwave electrometer with inherent uncertainty approaching its ultimate limit carries both fundamental and technological significance. However, because of the thermal motion of atoms, the state-of-art Rydberg electrometer falls considerably short of the standard quantum limit by about three orders of magnitude. Here, we use an optically thin medium with approximately 5.

View Article and Find Full Text PDF

In-vessel design of a two-color heterodyne laser interferometer system for SPARC.

Rev Sci Instrum

December 2024

Commonwealth Fusion Systems, Devens, Massachusetts 01434, USA.

This article covers the in-vessel design of the SPARC interferometry diagnostic system, highlighting unique aspects of the systems design and port plug integration in preparation for "day-1" plasma operations as a critical diagnostic for density feedback control. An early decision for the diagnostic was to deploy two lasers in the infrared wavelength spectrum, allowing the system to have a higher optical throughput. The optimization of the in-vessel geometry for the diagnostic follows a similar approach, focusing on de-risking possible damage to the plasma facing optical components by moving them further from the plasma with an orientation that provides a greater possibility for protective features to be added.

View Article and Find Full Text PDF

A heterodyne laser Doppler vibrometer (LDV) with a Bragg cell has a stationary signal carrier at a frequency of at least 35 MHz. The expensive Bragg cell with the restricted shift frequency is not an optimal solution to meet the requirements for many measurement scenarios. For vibrations with low frequencies and small amplitudes, a tens-of-megahertz carrier frequency not only wastes bandwidth at the photodetector but also requires a fast and expensive analog-to-digital converter (ADC).

View Article and Find Full Text PDF

A photonic-assisted scheme based on optical frequency shift heterodyne and low-frequency power mapping is proposed and experimentally demonstrated to measure the Doppler frequency shift (DFS) and Angle-of-arrival (AOA) of the microwave signals. In the proposed system, the optical signal is divided into two paths. The upper optical signal is injected into a dual-drive Mach-Zehnder modulator (DDMZM) and modulated by the two echo signals with a phase difference.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!