The degradation behavior of polyacrylamide (PAM) solution by low-temperature plasma was investigated, and the effect of some factors that might affect the degradation process was further examined. The PAM solution was treated with low-temperature plasma generated by dielectric barrier discharge (DBD) combined with HO and a Mn + Cu/AC composite catalyst. The optimal conditions for the oxidation degradation of a PAM solution using low-temperature plasma-HO-Mn + Cu/AC were determined as follows: initial concentration of 1000 mg/L, discharge voltage of 18 kV, HO addition of 2%, and catalyst addition of 810 mg. The results indicated that the degradation rate increased with the increase of the catalyst dosage at the same discharge time. The degradation rate of 180 min increases from 90 to 97.6% with an increase in voltage from 16 to 18 kV, and the molecular weight decreases from 2,720,204.23 to 1,370,815.54. The degradation effect caused by the change of HO addition was considerable compared with other factors. When the discharge time was 180 min, the degradation rate increased 26.3% with the increase of 1.6% HO addition. Under the optimal process conditions, the addition of the catalyst resulted in a more rapid initial decrease in the pH value of the solution compared to the system without the catalyst.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-023-30287-0DOI Listing

Publication Analysis

Top Keywords

pam solution
12
degradation rate
12
degradation
8
solution low-temperature
8
low-temperature plasma
8
voltage 18 kv
8
addition catalyst
8
rate increased
8
discharge time
8
catalyst
5

Similar Publications

Introduction: Prescribable digital health applications (DiGAs) present scalable solutions to improve patient self-management in rheumatology, however real-world evidence is scarce. Therefore, we aimed to assess the effectiveness, usage, and usability of DiGAs prescribed by rheumatologists, as well as patient satisfaction.

Methods: The DiGAReal registry includes adult patients with rheumatic conditions who received a DiGA prescription.

View Article and Find Full Text PDF

CRISPR-Cas enzymes must recognize a protospacer-adjacent motif (PAM) to edit a genomic site, significantly limiting the range of targetable sequences in a genome. Machine learning-based protein engineering provides a powerful solution to efficiently generate Cas protein variants tailored to recognize specific PAMs. Here, we present Protein2PAM, an evolution-informed deep learning model trained on a dataset of over 45,000 CRISPR-Cas PAMs.

View Article and Find Full Text PDF

Preparation and performance study of carboxymethylated Napier grass (Pennisetum purpureum) cellulose dust suppressant.

Int J Biol Macromol

January 2025

College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266590, China; State Key Laboratory of Mining Disaster Prevention and Control Co-found by Shandong Province and the Ministry of Science and Technology, Shandong University of Science and Technology, Qingdao 266590, China. Electronic address:

Coal mines generate significant amounts of dust during production, transportation, and stockpiling, leading to health hazards and environmental pollution. To address the inefficiencies and environmental impact of current chemical dust suppressants, a novel dust suppressant was developed utilizing cellulose derived from Napier grass (NG), modified through carboxymethylation, and supplemented with polyvinyl alcohol (PVA) and polyacrylamide (PAM). Orthogonal experiments identified the optimal ratio of sodium carboxymethyl cellulose (CMC), PAM, PVA, and octyl phenol polyoxyethylene ether (JFC-1) as 1:0.

View Article and Find Full Text PDF

To balance the stability and dissolution of polyacrylamide (PAM), emulsion drag reducers dominate the successful operation of volumetric fracturing. Herein, a pH-switchable four-tailed ionic liquid surfactant (OA/Cyclen) is synthesized by oleic acid (OA) and 1,4,7,10-tetraazacyclododecane (Cyclen). The four-tailed structure of OA/Cyclen enhances the stability of the emulsion polymerization reactor and supplies enough switchable sites for triggering the intensified release of the PAM emulsion.

View Article and Find Full Text PDF

Large language models (LLMs) have shown promise in medical question answering, with Med-PaLM being the first to exceed a 'passing' score in United States Medical Licensing Examination style questions. However, challenges remain in long-form medical question answering and handling real-world workflows. Here, we present Med-PaLM 2, which bridges these gaps with a combination of base LLM improvements, medical domain fine-tuning and new strategies for improving reasoning and grounding through ensemble refinement and chain of retrieval.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!