Introduction: A retrospective study to compare the classification, as normal, hypoplastic or aplastic, of thoracic (T10-T13) caudal articular process (CAP) morphology in Pug dogs with a thoracolumbar myelopathy as normal, hypoplastic or aplastic, between T2 weighted Turbo Spin Echo (T2W-TSE), in sagittal and transverse planes, and Volumetric Interpolated Breath-hold Examination (VIBE) Magnetic Resonance Imaging (MRI) sequences, in comparison to Computed Tomography (CT). We hypothesized a stronger agreement for VIBE in comparison to T2W-TSE.

Results: Diagnostic accuracy of T2W-TSE was inferior to VIBE for aplastic (60%, 95% CI 0.561-0.639 vs. 78%, 95%CI 0.744-0.815) hypoplastic (44%, 95%CI 0.427-0.452 vs. 62.5%, 95%CI 0.595-0.655) and normal CAP (70%, 95%CI 0.655-0.744 vs. 87%, 95%CI 0.848-0.892). Superior accuracy of classification using VIBE vs. T2W-TSE sequences using the McNemar Chi squared test was significant for aplastic ( = 0.0002) and normal CAP ( = 0.004). VIBE sequences had a sensitivity of 96% and specificity of 75% to detect CAP abnormality and with T2W-TSE imaging sensitivity 81% and specificity of 75%.

Discussion: Three-dimensionally reconstructable VIBE sequences were significantly more accurate than traditional T2W-TSE MRI sequences in classifying CAP morphology, which should reduce the need for CT for pre-operative assessment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10565115PMC
http://dx.doi.org/10.3389/fvets.2023.1265665DOI Listing

Publication Analysis

Top Keywords

turbo spin
8
spin echo
8
volumetric interpolated
8
interpolated breath-hold
8
breath-hold examination
8
magnetic resonance
8
resonance imaging
8
articular process
8
pug dogs
8
dogs thoracolumbar
8

Similar Publications

Purpose: The present work aims to evaluate the performance of three-dimensional (3D) single-shot stack-of-spirals turbo FLASH (SOS-TFL) acquisition for pseudo-continuous arterial spin labeling (PCASL) and velocity-selective ASL (VSASL)-based cerebral blood flow (CBF) mapping, as well as VSASL-based cerebral blood volume (CBV) mapping.

Methods: Digital phantom simulations were conducted for both multishot echo planar imaging and spiral trajectories with intershot signal fluctuations. PCASL-derived CBF (PCASL-CBF), VSASL-derived CBF (VSASL-CBF), and CBV (VSASL-CBV) were all acquired using 3D multishot gradient and spin-echo and SOS-TFL acquisitions following background suppression.

View Article and Find Full Text PDF

Purpose: To evaluate accelerated T- and T-mapping techniques for ultra-low-field MRI using low-rank reconstruction methods.

Methods: Two low-rank-based algorithms, image-based locally low-rank (LLR) and k-space-based structured low-rank (SLR), were implemented to accelerate T and T mapping on a 46 mT Halbach MRI scanner. Data were acquired with 3D turbo spin-echo sequences using variable-density poisson-disk random sampling patterns.

View Article and Find Full Text PDF

Nexus: A versatile console for advanced low-field MRI.

Magn Reson Med

January 2025

Department 8.1 - Biomedical Magnetic Resonance, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.

Purpose: To develop a low-cost, high-performance, versatile, open-source console for low-field MRI applications that can integrate a multitude of different auxiliary sensors.

Methods: A new MR console was realized with four transmission and eight reception channels. The interface cards for signal transmission and reception are installed in PCI Express slots, allowing console integration in a commercial PC rack.

View Article and Find Full Text PDF

Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness. MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla.

View Article and Find Full Text PDF

Background And Objective: Radiosurgery can serve as a primary, adjuvant, or salvage treatment modality for cavernous sinus tumors (CST), providing high tumor control. However, particularly with cavernous sinus expansion, there may be insufficient distance from the optic apparatus to perform radiosurgery safely. The internal carotid artery adjacent to the distal dural ring (ICAddr), when enhancing similarly to the CST, can be difficult to delineate, and can lead to over-contouring of target volume near the optic nerve and therefore increasing the risk of radiation-induced optic toxicity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!