Objectives: The purpose of this study was to investigate the safety and early clinical results from the use of a novel, noble metal-coated titanium tibial nail for the definite stabilization of tibial shaft fractures at risk of developing complications.
Design: This is a retrospective case series with prospectively collected data.
Setting: Level I Trauma Centre in the United Kingdom.
Patients And Intervention: Thirty-one patients who were managed with the Bactiguard-coated Natural Nail and achieved a minimum of a 12-month follow-up.
Main Outcome Measurements: The main outcomes of this study were the incidence of adverse events (related to implant safety), complications (particularly infection), and reinterventions.
Results: Thirty-one patients with a mean age of 41.6 years were included in this study. Active heavy smokers or intravenous drug users were 25.8% and 9.7% of them were diabetic. Five fractures were open while 13 had concomitant soft-tissue involvement (Tscherne grade 1 or 2). Twenty-seven patients healed with no further intervention in a mean time of 3.3 months. Three patients developed nonunion and required further intervention. The overall union rate was 96.7%. One patient developed deep infection after union (infection incidence 3.2%). Six patients (6/31; [19.3%]) required reinterventions [2 for the treatment of nonunion, 3 for removal of screws soft-tissue irritation, and 1 for the management of infection).
Conclusions: The management of tibial shaft fractures with a noble metal-coated titanium tibial nail demonstrates encouraging outcomes. Further studies are desirable to gather more evidence in the performance of this innovative implant.
Level Of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BOT.0000000000002688 | DOI Listing |
Arthrosc Tech
December 2024
Department for Orthopedics and Trauma Surgery, Martin Luther Hospital Berlin, Berlin, Germany.
Indication for this hemi-wedge high tibial osteotomy is the combination of medial osteoarthritis or cartilage damage, varus deformity of >10°, and medial proximal tibial angle of <80°. The proximal lateral tibia is exposed via a skin incision of approximately 10 cm length between the tibial tuberosity and the head of the fibula. After detachment of the anterior tibial muscle, a first oblique guidewire marks the main osteotomy plane and a second guidewire marks the hemi-wedge.
View Article and Find Full Text PDFArthrosc Tech
December 2024
Department of Orthopaedics, University Hospital of Florence - A.O.U. Careggi, Florence, Italy.
Revision of anterior cruciate ligament reconstruction presents various challenges not encountered in the primary settings, including malpositioned tunnels, tunnel widening, and the lack of consensus on the ideal graft to be used. This Technical Note describes a one-stage anterior cruciate ligament reconstruction revision using a bone-patellar tendon-bone autograft combined with lateral extra-articular tenodesis. This technique represents the ideal approach to tackle complex revision cases primarily characterized by tibial and femoral tunnel osteolysis and rotational knee instability.
View Article and Find Full Text PDFJ Med Case Rep
January 2025
Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya University Hospital, 65 Tsurumai, Showa, Nagoya, Aichi, 466-8550, Japan.
Background: The Compress is designed to achieve bone formation and stability by applying pressure at the bone-implant interface, minimizing the likelihood of aseptic loosening, which is a complication of stem implants. Herein, we report two cases of implant failure using the Compress.
Case Presentation: Case 1 describes a 36 year-old Japanese man who underwent extraarticular tumor resection, Compress arthroplasty, and reconstruction with a gastrocnemius flap after preoperative chemotherapy for a secondary malignant giant cell tumor in the right distal femur.
Eur J Trauma Emerg Surg
January 2025
Department of Orthopaedics, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China.
Purpose: (1) To evaluate the incidence and combination types of concomitant malleolar and fibular fractures in patients with distal spiral tibial shaft fractures. (2) To evaluate the risk factors for concomitant malleolar fractures in patients with distal spiral tibial shaft fractures.
Methods: A retrospective review was performed on 64 cases of surgically treated distal spiral tibial shaft fractures with complete radiographs and computed tomography (CT) scans.
Unfallchirurgie (Heidelb)
January 2025
Klinik für Orthopädie und Unfallchirurgie, Departement Chirurgie, Kantonsspital Graubünden, Loëstrasse 170, Chur, Schweiz.
Pilon fractures typically result from high-energy trauma combined with axial compression. The surrounding soft tissues are often severely compromised, complicating treatment. These fractures are best classified according to the Working Group for Osteosynthesis Issues/Orthopedic Trauma Association (AO/OTA) classification system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!