Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The emergence of "superbugs" due to antibiotics overuse poses a significant threat to human health and security. The development of sensitive and effective antibiotics detection is undoubtedly a prerequisite for addressing antibiotics overuse-associated issues. However, current techniques for monitoring antibiotics typically require costly equipment and well-trained professionals. Hence, we developed herein a rapid, instrument-free, and on-site detection method for antibiotic residues such as norfloxacin (NOR) based on a ratiometric sensing platform utilizing "on-off-on" response properties of polychromatic fluorescence for direct visual quantitative NOR analysis. Specifically, this platform integrated iron ions (Fe)-chelated blue carbon dots (BCDs) for signal sensing and red carbon dots (RCDs) as an internal reference. The sensor mechanism is selective quenching of BCDs' blue fluorescence by Fe via an inner filter effect with unaffected RCDs' red fluorescence. Further NOR addition led to competitive binding with BCDs due to Fe shedding from the BCDs' surface for a recovered blue fluorescence signal. Notably, the ratiometric fluorescence sensor demonstrated rapid and highly sensitive NOR detection in a concentration range of 1-70 μM with an impressive detection limit of 6.84 nM. The ratiometric fluorescence sensing platform was constructed by integrating smartphone and paper-based strategies, which exhibited exceptional sensitivity, selectivity, and rapid response for portable, instrument-free, visual quantification of NOR in real samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2023.341837 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!