A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Peak oxygen consumption by smartwatches compared with cardiopulmonary exercise test in complex congenital heart disease. | LitMetric

Objective: To evaluate for correlation between exercise capacity as assessed by peak oxygen consumption (pVO) measurement during a cardiopulmonary exercise test (CPET) and smartwatches reporting this parameter in patients with adult congenital heart disease (ACHD) complex lesions.

Methods: A prospective study that included patients with ACHD either a Fontan circulation or a right ventricle supporting the systemic circulation who underwent two separate CPETs at least 1 year apart. Generalised estimating equations linear regression was performed to identify factors associated with correlation between smartwatch and CPET-derived pVO.

Results: 48 patients (71% with a Fontan circulation, 42% females, mean age 33±9 years) underwent two CPETs between May 2018 and May 2022 with echocardiograms performed within 6 months of each CPET. Apple Watch was the predominant smartwatch used (79%). Smartwatch and CPET measured peak heart rate (Pearson correlation=0.932, 95% CI (0.899, 0.954)) and pVO (0.8627, 95% CI (0.8007, 0.9064) and 0.8634, 95% CI (0.7676, 0.9215) in the first and second CPET, respectively) correlated well, with smartwatch-measured pVO values measuring higher by a mean of 3.146 mL/kg/min (95% CI (2.559, 3.732)). Changes in pVO between the first and the second CPET also correlated well (Pearson correlation=0.9165, 95% CI (0.8549, 0.9525)), indicating that for every 1 mL/(min kg) change in CPET-measured pVO, there was a corresponding 0.896 mL/(min kg) change in the smartwatch-measured pVO.

Conclusion: Both absolute values and changes over time in pVO as measured by smartwatches and CPETs correlate well in patients with complex ACHD.

Download full-text PDF

Source
http://dx.doi.org/10.1136/heartjnl-2023-322989DOI Listing

Publication Analysis

Top Keywords

peak oxygen
8
oxygen consumption
8
cardiopulmonary exercise
8
exercise test
8
congenital heart
8
heart disease
8
fontan circulation
8
second cpet
8
cpet correlated
8
correlated well
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!