Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: A typical problem in the registration of MRI and X-ray mammography is the nonlinear deformation applied to the breast during mammography. We have developed a method for virtual deformation of the breast using a biomechanical model automatically constructed from MRI. The virtual deformation is applied in two steps: unloaded state estimation and compression simulation. The finite element method is used to solve the deformation process. However, the extensive computational cost prevents its usage in clinical routine.
Methods: We propose three machine learning models to overcome this problem: an extremely randomized tree (first model), extreme gradient boosting (second model), and deep learning-based bidirectional long short-term memory with an attention layer (third model) to predict the deformation of a biomechanical model. We evaluated our methods with 516 breasts with realistic compression ratios up to 76%.
Findings: We first applied one-fold validation, in which the second and third models performed better than the first model. We then applied ten-fold validation. For the unloaded state estimation, the median RMSE for the second and third models is 0.8 mm and 1.2 mm, respectively. For the compression, the median RMSE is 3.4 mm for both models. We evaluated correlations between model accuracy and characteristics of the clinical datasets such as compression ratio, breast volume, and tissue types.
Interpretation: Using the proposed models, we achieved accurate results comparable to the finite element model, with a speedup of factor 240 using the extreme gradient boosting model. These proposed models can replace the finite element model simulation, enabling clinically relevant real-time application.