A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Estimation of the biomechanical mammographic deformation of the breast using machine learning models. | LitMetric

Background: A typical problem in the registration of MRI and X-ray mammography is the nonlinear deformation applied to the breast during mammography. We have developed a method for virtual deformation of the breast using a biomechanical model automatically constructed from MRI. The virtual deformation is applied in two steps: unloaded state estimation and compression simulation. The finite element method is used to solve the deformation process. However, the extensive computational cost prevents its usage in clinical routine.

Methods: We propose three machine learning models to overcome this problem: an extremely randomized tree (first model), extreme gradient boosting (second model), and deep learning-based bidirectional long short-term memory with an attention layer (third model) to predict the deformation of a biomechanical model. We evaluated our methods with 516 breasts with realistic compression ratios up to 76%.

Findings: We first applied one-fold validation, in which the second and third models performed better than the first model. We then applied ten-fold validation. For the unloaded state estimation, the median RMSE for the second and third models is 0.8 mm and 1.2 mm, respectively. For the compression, the median RMSE is 3.4 mm for both models. We evaluated correlations between model accuracy and characteristics of the clinical datasets such as compression ratio, breast volume, and tissue types.

Interpretation: Using the proposed models, we achieved accurate results comparable to the finite element model, with a speedup of factor 240 using the extreme gradient boosting model. These proposed models can replace the finite element model simulation, enabling clinically relevant real-time application.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2023.106117DOI Listing

Publication Analysis

Top Keywords

finite element
12
model
10
deformation breast
8
machine learning
8
learning models
8
deformation applied
8
virtual deformation
8
biomechanical model
8
unloaded state
8
state estimation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!