We instituted the use of a power injector during dynamic body CT to improve control of the rate of contrast injection, to make it unnecessary for a technologist to remain in the gantry room during scanning, and to make it possible for one technologist to simultaneously perform the injection and operate the scanner. We analyzed the first 240 cases using the power injector for quality of contrast enhancement and frequency of complications, including contrast material extravasation into soft tissues. Ninety-seven percent of the studies had enhancement judged good, very good, or excellent. A technologist remained in the gantry room during some portion of the examination in only 11% of the studies. Minor contrast material extravasation occurred in two cases and major extravasation in one case, a frequency of 1.3%. None of these resulted in long-term morbidity.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004728-198611000-00020DOI Listing

Publication Analysis

Top Keywords

power injector
12
injector dynamic
8
gantry room
8
contrast material
8
material extravasation
8
dynamic computed
4
computed tomography
4
tomography instituted
4
instituted power
4
dynamic body
4

Similar Publications

Background: Botulinum toxin is commonly used for cosmetic enhancements in various applications. However, the pain experienced during the injection process remains a significant concern.

Objective: This study aimed to evaluate the effectiveness and safety of a needle-free microjet drug injector, powered by an Er:YAG laser, for the injection of botulinum toxin to treat crow's feet wrinkles.

View Article and Find Full Text PDF

Introduction to iodinated contrasts: Properties, intravenous administration and distribution throughout the body.

Radiologia (Engl Ed)

October 2024

Servicio de Radiodiagnóstico, Hospital General Universitario Dr. Balmis de Alicante; Departamento de Patología y Cirugía, Universidad Miguel Hernández; Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain. Electronic address:

Iodinated contrast media enable greater attenuation of vascular and visceral structures in radiological studies and are widely used due to their high degree of safety, easy administration, acceptable level of tolerance, wide distribution and rapid excretion, qualities determined by their composition. Automated power injectors are used to administer contrast media. Once injected, contrast is distributed throughout the body, remaining in the intravascular space during its first passage before reaching the organs and spreading into the extracellular interstitial space, followed by a recirculation phenomenon.

View Article and Find Full Text PDF

To reveal the penetration mechanism and present the penetration characteristics of high-speed micro-jet with injection volume larger than 0.3 mL into soft tissue, the present study conducted experimental research on high-speed water-jet penetration into ballistic gelatin. The free jet dynamics of an air-powered needle-free injector that can emit up to 1.

View Article and Find Full Text PDF

SPring-8-II is a major upgrade project of SPring-8 that was inaugurated in October 1997 as a third-generation synchrotron radiation light source. This upgrade project aims to achieve three goals simultaneously: achievement of excellent light source performance, refurbishment of aged systems, and significant reduction in power consumption for the entire facility. A small emittance of 50 pm rad will be achieved by (1) replacing the existing double-bend lattice structure with a five-bend achromat one, (2) lowering the stored beam energy from 8 to 6 GeV, (3) increasing the horizontal damping partition number from 1 to 1.

View Article and Find Full Text PDF

Background: There is emerging evidence for the potential utility of left bundle branch area pacing (LBBAP), as an alternative to conventional cardiac resynchronization therapy (CRT). The utility of right ventriculography by way of power injector to facilitate lead placement has not yet been reported in the literature.

Case Summary: A 79-year-old female, with a background of poorly rate-controlled atrial fibrillation, presented with worsening dyspnoea.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!