Severity: Warning
Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Proficiency testing (PT) is a tool for ensuring the validity of results of testing laboratories and is essential when laboratories are working with assays authorised for emergency use or implementing novel techniques for detecting emerging pathogens.
Methods: In collaboration with the National Health Institute of Colombia and with international support, we developed a qualitative PT for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by reverse transcription polymerase chain reaction (RT-PCR). A proficiency test item (PTI) based on reference material (research grade) produced by the National Institute of Standards and Technologies (NIST) was prepared and characterised using three positive samples with varying concentrations of SARS-CoV-2 ribonucleic acid (RNA) and two negative (control) samples. Tests were distributed to 121 laboratories across the national network of public health laboratories in Colombia.
Results: Positive samples had varying concentrations of SARS-CoV-2 RNA and were quantified by digital PCR (RT-ddPCR) assays for the E gene of SARS-CoV-2. We tested the ability of laboratories to detect low and high levels of viral RNA using samples with SARS-CoV-2 RNA concentrations of 1417 ± 216, 146 ± 28, and 14 ± 10 copies /uL (expanded uncertainty, k = 2, 95% confidence level) We also performed a semiquantitative analysis of instrumental responses (Ct values) reported by participating laboratories and homogeneity, stability, and characterisation studies of the produced materials to determine the adequacy of these materials and methods for use in the qualitative PT scheme. The PT evaluated reports for individual target genes from each laboratory; 98.3% of laboratories had satisfactory performance and the remaining 1.7% of laboratories had unsatisfactory performance for the detection of at least one of the reported genes.
Conclusions: This PT scheme identified the potential metrological weaknesses of laboratories in the detection of SARS-CoV-2 by RT-PCR and may facilitate improvements in the quality of measurements from the perspective of public health surveillance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10569378 | PMC |
http://dx.doi.org/10.7189/jogh.13.06029 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!