Compression sonography has been proposed as a method for non-invasive measurement of venous pressures during spaceflight, but initial reports of venous pressure measured by compression ultrasound conflict with prior reports of invasively measured central venous pressure (CVP). The aim of this study is to determine the agreement of compression sonography of the internal jugular vein (IJVP) with invasive measures of CVP over a range of pressures relevant to microgravity exposure. Ten healthy volunteers (18-55 years, five female) completed two 3-day sessions of supine bed rest to simulate microgravity. IJVP and CVP were measured in the seated position, and in the supine position throughout 3 days of bed rest. The range of CVP recorded was in line with previous reports of CVP during changes in posture on Earth and in microgravity. The correlation between IJVP and CVP was poor when measured during spontaneous breathing (r = 0.29; R  = 0.09; P = 0.0002; standard error of the estimate (SEE) = 3.0 mmHg) or end-expiration CVP (CVP ; r = 0.19; R  = 0.04; P = 0.121; SEE = 3.0 mmHg). There was a modest correlation between the change in CVP and the change in IJVP for both spontaneous ΔCVP (r = 0.49; R  = 0.24; P < 0.0001) and ΔCVP (r = 0.58; R  = 0.34; P < 0.0001). Bland-Altman analysis of IJVP revealed a large positive bias compared to spontaneous breathing CVP (3.6 mmHg; SD = 4.0; CV = 85%; P < 0.0001) and CVP (3.6 mmHg; SD = 4.2; CV = 84%; P < 0.0001). Assessment of absolute IJVP via compression sonography correlated poorly with direct measurements of CVP by invasive catheterization over a range of venous pressures that are physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time. NEW FINDINGS: What is the central question of this study? Compression sonography has been proposed as a novel method for non-invasive measurement of venous pressures during spaceflight. However, the accuracy has not yet been confirmed in the range of CVP experienced by astronauts during spaceflight. What is the main finding and its importance? Our data show that compression sonography of the internal jugular vein correlates poorly with direct measurement of central venous pressures in a range that is physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10988448PMC
http://dx.doi.org/10.1113/EP091372DOI Listing

Publication Analysis

Top Keywords

venous pressure
12
compression sonography
12
bed rest
12
cvp
9
sonography internal
8
internal jugular
8
jugular vein
8
3 days bed
8
ijvp cvp
8
assessment venous
4

Similar Publications

A Multi-Scale Computational Model of the Hepatic Circulation Applied to Predict the Portal Pressure After Transjugular Intrahepatic Portosystemic Shunt (TIPS).

Int J Numer Method Biomed Eng

January 2025

Hebei Provincial Key Laboratory of Portal Hypertension and Cirrhosis, Xingtai People's Hospital, Xingtai, China; Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nanjing, China.

Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertension. In clinical practice, the diameter of the stent forming a shunt is usually selected empirically, which will influence the postoperative portal pressure. Clinical studies found that inappropriate portal pressure after TIPS is responsible for poor prognosis; however, there is no scheme to predict postoperative portal pressure.

View Article and Find Full Text PDF

Direct Axillary Artery Cannulation as Standard Perfusion Strategy in Minimally Invasive Coronary Artery Bypass Grafting.

J Cardiovasc Dev Dis

January 2025

Department of Cardiothoracic Surgery, Heart-Thorax Center, Klinikum Fulda, University Medicine Marburg, Campus Fulda, 36043 Fulda, Germany.

Objective: Cardiopulmonary bypass (CPB) via the right axillary artery (RAA) has become an alternative perfusion strategy, especially in complex aortic procedures. This study delineates our technique and outcome with direct axillary cannulation utilizing the Seldinger technique, which we adopted as the standard perfusion strategy in the sternum-sparing minimally invasive total coronary revascularization via left anterior thoracotomy (TCRAT) using CPB.

Methods: From November 2019 to December 2023, a total of 413 consecutive patients underwent nonemergent isolated coronary artery bypass grafting (CABG) via left anterior minithoracotomy on CPB with peripheral cannulation via the RAA and cardioplegic cardiac arrest, using this technique as a default strategy in the daily routine.

View Article and Find Full Text PDF

The aim of this study was to investigate the locational distribution and potential mechanisms of retinal hemorrhages in newborns using fundus photography. A retrospective analysis of 98 consecutive newborns with retinal hemorrhages in at least one eye and 30 control newborns without retinal hemorrhages after uneventful delivery was conducted. Retinal hemorrhages were diagnosed and characterized using fundus photography and indirect ophthalmoscopy.

View Article and Find Full Text PDF

Progressive systemic inflammation precedes decompensation in compensated cirrhosis.

JHEP Rep

February 2025

Department of Gastroenterology and Hepatology, Hospital Universitario Ramón y Cajal, Instituto Ramon y Cajal de Investigación Sanitaria (IRYCIS), Universidad de Alcalá, Madrid, Spain.

Background & Aims: Systemic inflammation is a driver of decompensation in cirrhosis with unclear relevance in the compensated stage. We evaluated inflammation and bacterial translocation markers in compensated cirrhosis and their dynamics in relation to the first decompensation.

Methods: This study is nested within the PREDESCI trial, which investigated non-selective beta-blockers for preventing decompensation in compensated cirrhosis and clinically significant portal hypertension (CSPH: hepatic venous pressure gradient ≥10 mmHg).

View Article and Find Full Text PDF

Shunt dependence syndrome is a serious long-term complication characterized by symptoms and signs of increased intracranial pressure with normal-sized lateral ventricles after several years of arachnoid cyst-peritoneal shunting. It is easy to misdiagnose and overlook when combined with sinus stenosis, thus delaying treatment. Here, we present a 35-year-old man with an unexplained headache and binocular horizontal diplopia with high intracranial pressure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!