In response to the ICRP's amending the occupational exposure limit for the eye lens, the Institute of Nuclear Energy Research (INER) established the Hp(3) calibration system for eye dose monitoring in Taiwan to accurately assess the dose received in the eye lens. INER employed the narrow-spectrum series radiation according to the ISO 4037 as the X-ray radiation qualities, and the measured half-value layer consistent with a 5% difference. The air kerma rate standard was determined by the self-made free air chamber, and through dose conversion coefficient referring to ISO 4037 to obtain the Hp(3) on an ISO cylinder phantom. Furthermore, the calibration system was provided as the characteristics tests for DOSIRIS headset dosemeters. Finally, the Hp(3) calibration system has been established in Taiwan, and it can be used to provide calibration services for eye lens dosemeters and be applied to the proficiency testing that will be held in 2023.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncad066DOI Listing

Publication Analysis

Top Keywords

calibration system
16
hp3 calibration
12
eye lens
12
system eye
8
eye dose
8
dose monitoring
8
monitoring taiwan
8
iso 4037
8
calibration
5
eye
5

Similar Publications

Low-temperature on-site in situ high-pressure ultrafast pump-probe spectroscopy instrument.

Rev Sci Instrum

January 2025

Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China.

We design and construct an ultrafast optical spectroscopy instrument that integrates both on-site in situ high-pressure technique and low-temperature tuning capability. Conventional related instruments rely on off-site tuning and calibration of the high pressure. Recently, we have developed an on-site in situ technique, which has the advantage of removing repositioning fluctuation.

View Article and Find Full Text PDF

Cryo-SIMPLY: A Reliable STT-MRAM-Based Smart Material Implication Architecture for In-Memory Computing.

Nanomaterials (Basel)

December 2024

Department of Computer Engineering, Modeling, Electronics, and Systems Engineering, University of Calabria, 87036 Rende, Italy.

This paper presents Cryo-SIMPLY, a reliable smart material implication (SIMPLY) operating at cryogenic conditions (77 K). The assessment considers SIMPLY schemes based on spin-transfer torque magnetic random access memory (STT-MRAM) technology with single-barrier magnetic tunnel junction (SMTJ) and double-barrier magnetic tunnel junction (DMTJ). Our study relies on a temperature-aware macrospin-based Verilog-A compact model for MTJ devices and a 65 nm commercial process design kit (PDK) calibrated down to 77 K under silicon measurements.

View Article and Find Full Text PDF

A compact dual-gas sensor based on the two near-infrared distributed feedback diode lasers and a multipass cell has been established for the simultaneous measurement of methane (CH) and acetylene (CH). The time division multiplexing calibration-free direct absorption spectroscopy is used to eliminate the cross interference in the application of multicomponent gas sensors. A wavelength stabilization technique based on the proportion integration differentiation feedback control is developed to suppress laser wavelength drift and an H-infinity (H) filter algorithm to reduce the system noise.

View Article and Find Full Text PDF

Background: While existing risk calculators focus on mortality and complications, elderly patients are concerned with how operations will affect their quality of life, especially their independence. We sought to develop a novel clinically relevant and easy-to-use score to predict elderly patients' loss of independence after gastrointestinal surgery.

Methods: This retrospective cohort study included patients age ≥ 65 years enrolled in the American College of Surgeons National Surgical Quality Improvement Program database and Geriatric Pilot Project who underwent pancreatic, colorectal, or hepatic surgery (January 1, 2014- December 31, 2018).

View Article and Find Full Text PDF

Commutability is where the measurement response for a reference material (RM) is the same as for an individual patient sample with the same concentration of analyte measured using two or more measurement systems. Assessment of commutability is essential when the RM is used in a calibration hierarchy or to ensure that clinical measurements are comparable across different measurement procedures and at different times. The commutability of three new Standard Reference Materials (SRMs) for determining serum total 25-hydroxyvitamin D [25(OH)D], defined as the sum of 25-hydroxyvitamin D [25(OH)D] and 25-hydroxyvitamin D [25(OH)D], was assessed through an interlaboratory study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!