In a nuclear or radiological accident scenario, when potentially members of the public can undergo internal contamination by anthropogenic radionuclides released in the atmosphere, effective methods that can be used directly in the field to perform a fast scan for internal contamination on a large number of individuals can play a major role to undertake appropriate countermeasures. Specific attention should be paid to the individual monitoring of children since they constitute the sensitive population group with the highest risk of developing cancer. At the ENEA Casaccia Research Center in Rome (Italy), monitoring procedures based on a portable HPGe detector and ratemeters were tested in the field. A total of 170 acquisitions of uncontaminated volunteers for the blank measurements were collected, 105 acquisitions on adult and 65 acquisitions on 10-y/o children. The detection limit calculation, in terms of activity taken up (Bq), was carried out according to the Standard ISO's 11929 and 28218, whereas the corresponding 'minimum effective dose' (mSv) was calculated based on international commission on radiological protection (ICRP) Publications 134, 137 and 141. Results and evaluations of the measurement campaign are presented and discussed in respect to the aspects reported in the current literature.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncac217 | DOI Listing |
JNCI Cancer Spectr
January 2025
Ruesch Center for the Cure of Gastrointestinal Cancers, Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, DC.
Since the early 1990s, there has been a dramatic rise in gastrointestinal cancers diagnosed in patients under age 50 for reasons that remain poorly understood. The most significant change has been the increase in incidence rates of early-onset colorectal cancer, especially rates of left-sided colon and rectal cancers. Increases in gastric, pancreatic, and other gastrointestinal cancer diagnoses have further contributed to this trend.
View Article and Find Full Text PDFJAMA Netw Open
January 2025
Department of Medicine, Division of Infectious Diseases, Johns Hopkins University School of Medicine, Baltimore, Maryland.
Importance: Blood culture (BC) use benchmarks in US hospitals have not been defined.
Objective: To characterize BC use in adult intensive care units (ICUs) and wards in US hospitals.
Design, Setting, And Participants: A retrospective cross-sectional study of BC use in adult medical ICUs, medical-surgical ICUs, medical wards, and medical-surgical wards from acute care hospitals from the 4 US geographic regions was conducted.
J Agric Food Chem
January 2025
College of Ocean Food and Biological Engineering, Jimei University, Xiamen 361021, China.
In this study, we present an intelligent electromagnetic-actuated microfluidic chip integrated with a G-quadruplex DNAzyme-based biocatalysis platform for rapid and sensitive tetracycline (TC) detection. In this sensing system, TC significantly quenches fluorescent magnetic carbon dots (M-CDs) via the internal filtration effect and dynamic quenching (the excitation and emission wavelength at 350 and 440 nm, respectively). Then, the G-quadruplex on the M-CDs-Aptamer is exposed and bound with hemin to form hemin-G-quadruplex DNAzyme, catalyzing the conversion of 3,3',5,5'-tetramethylbenzidine to produce blue color.
View Article and Find Full Text PDFMedicine (Baltimore)
November 2024
Department of Colorectal Surgery, The First Affiliated Hospital of Shandong First Medical University, Jinan, China.
Rationale: Retained rectal foreign bodies (RFBs) are unusual clinical presentations whose management is challenging for emergency physicians owing to variations in the object types, anorectal anatomy, sacral curvature, insertion times, and local contamination. Here, we present the diagnosis and treatment in 1 case of retained rectal foreign body.
Patient Concerns: A 62-year-old male presented to the emergency department with a cosmetic bottle inserted into the rectum while bathing.
Health Phys
January 2025
National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing, 100088, China.
Inhalation of 131I is the main route for internal doses to nuclear medicine workers. This study aimed to establish a simple analysis method for determining 131I activity in carbon cartridges, explore the activity concentration of 131I in nuclear medicine departments, and evaluate the internal dose of workers. A total of 21 nuclear medicine departments in the hospital conducted air sampling using a high-volume air sampler equipped with carbon cartridges and glass fiber filters to collect gaseous 131I and aerosol 131I, respectively.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!