Unlabelled: A 74-year-old man who had undergone surgical aortic valve replacement with the SOLO SMART stentless bioprosthetic valve 25 mm (LivaNova PLC, London, UK) and mitral valve replacement with MOSAIC 29 mm (Medtronic, Minneapolis, USA) 4 years previously was diagnosed with congestive heart failure, and transferred to our hospital. Echocardiography revealed severe aortic regurgitation caused by degraded bioprosthetic valve. He required continuous dobutamine administration to maintain hemodynamics. As a result of heart team discussion, we decided to perform transcatheter valve-in-valve implantation (ViV-TAVI) using balloon expandable valve (Sapien 3, Edwards Lifesciences, Irvine, USA). Since SOLO SMART stentless valve was placed to Valsalva sinus at the supra-annular level with continuous sutures, we planned to anchor TAVI valve 4 mm to the left ventricular side from the bottom of the failed stentless valve. Two pigtail catheters were placed at the bottom of the failed stentless valve leaflet to mark the nadir of stentless valve. After ViV-TAVI, the patient no longer required catecholamine administration and was discharged home one month later. This is the first case of ViV-TAVI using balloon expandable valve for failed SOLO SMART stentless bioprosthetic valve in a Japanese patient.
Learning Objective: Transcatheter valve-in-valve implantation (ViV-TAVI) for stentless valves is known to be technically challenging due to poor fluoroscopic visibility. Because the SOLO SMART stentless bioprosthetic valve is sutured to the wall of the sinus of Valsalva above the annulus, the landing point of transcatheter heart valve is at a native annulus which is lower than the bottom of the SOLO SMART leaflet. We describe the first Japanese case of ViV-TAVI with balloon expandable valve for the SOLO SMART stentless bioprosthetic valve.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10562123 | PMC |
http://dx.doi.org/10.1016/j.jccase.2023.06.006 | DOI Listing |
3D Print Addit Manuf
August 2024
Department of Mechanical Engineering, Universitas Sebelas Maret, Solo, Indonesia.
This research is devoted to numerical and experimental analysis on deformation of completely removed component induced by wire arc additive manufacturing (WAAM). The component has the form of a hollow and rectangular thin wall made of deposition layer of stainless steel SS316L on top of substrate plate of mild steel S235. In this research, thermomechanical finite element analysis was applied with Goldak's double ellipsoid as heat-source model and isotropic hardening rule based on von-Mises yield criterion.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
September 2024
Department of Chemistry, City University of Hong Kong, Kowloon, Hong Kong, SAR 999077, China.
Anal Chim Acta
November 2023
Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkiye. Electronic address:
Background: Sorafenib (SOR) is a multikinase inhibitor anticancer drug that is used in treating non-small cell lung cancer. In this work, we focused on developing nanomaterial-supported smart porous interfaces by following the molecular imprinting approach for the selective determination of SOR. Determination-based studies in the literature for SOR are limited, and they are chromatographic techniques-based; hence, there is a need in the literature to elaborate the selective and sensitive analysis/monitoring of SOR in both biological and pharmaceutical samples with more studies.
View Article and Find Full Text PDFJ Cardiol Cases
October 2023
Department of Cardiology, Pulmonology, and Nephrology, Yamagata University School of Medicine, Yamagata, Japan.
Unlabelled: A 74-year-old man who had undergone surgical aortic valve replacement with the SOLO SMART stentless bioprosthetic valve 25 mm (LivaNova PLC, London, UK) and mitral valve replacement with MOSAIC 29 mm (Medtronic, Minneapolis, USA) 4 years previously was diagnosed with congestive heart failure, and transferred to our hospital. Echocardiography revealed severe aortic regurgitation caused by degraded bioprosthetic valve. He required continuous dobutamine administration to maintain hemodynamics.