A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Three-dimensional printed cast assisted screw fixation of calcaneal fractures: a prospective study. | LitMetric

Background: Treatment of displaced intra-articular calcaneal fractures (DIACFs) with percutaneous screw fixation remains defective in some aspects. A novel three-dimensional (3D) printed cast was devised to assist screw placement. This study assessed the radiological and functional outcomes of 3D-printed cast assisted screw fixation for patients with DIACFs.

Methods: Patients with unilateral Sanders type II or III DIACFs admitted to a single-centre hospital underwent either 3D-printed cast assisted screw fixation (3D group) or minimally invasive plate fixation (control group) from September 2020 to November 2022. All patients were assessed at one, two, three, and six months of follow-up. Comparison between groups was conducted in operative duration, fluoroscopic times, radiographic measurements of the calcaneus, and the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Score.

Results: A total of 32 patients were enrolled (19 in the 3D group versus 13 in the control group). Significant differences were detected between the 3D group and control group in operative duration (53.63±8.95 min, 95.08±8.31 min, P <0.001), fluoroscopic times (7.37±1.21, 16.85±1.57, P <0.001). At a follow-up of six months, the 3D group showed better restoration than the control group in calcaneal width, height, Bohler angle, and AOFAS Ankle-Hindfoot scores (all P <0.001). No significant differences were shown in calcaneal length and Gissane angle (P >0.05). No wound-related complications occurred in either group.

Conclusion: The 3D-printed cast assisted screw fixation has shown superiority over minimally invasive plate fixation in the operative duration, fluoroscopic exposure, morphological restoration of the calcaneus, and functional outcomes in the treatment of DIACFs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563275PMC
http://dx.doi.org/10.1186/s12891-023-06927-4DOI Listing

Publication Analysis

Top Keywords

screw fixation
16
cast assisted
12
assisted screw
12
control group
12
three-dimensional printed
8
printed cast
8
calcaneal fractures
8
3d-printed cast
8
operative duration
8
group
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!