Objective: Evaluation of structural and immunohistochemical features of cornea in Fuchs endothelial corneal dystrophy (FECD) and bullous keratopathy (BK).

Material And Methods: Group 1 - 44 patients (46 eyes) with FECD, group 2 - 42 patients (42 eyes) with BK. All patients underwent keratoplasty. Preoperative anterior segment optical coherence tomography (AS-OCT, RTVue-100, Optovue, USA) was performed. Endothelium-Descemet membrane (EDM) complexes, corneal buttons were obtained intraoperatively. Morphological (H&E staining) and immunohistochemical (primary antibodies to pancytokeratin, vimentin, fibronectin) studies were performed at the light microscope level (Leica DM-2500, Leica Application Suite V4.8, Leica Microsystems, Switzerland).

Results: A direct correlation is found between the results of DM analysis in vivo with OCT and ex vivo with light microscopy. DM thickness (AS-OCT) was significantly greater in FECD (23.0 [19.0; 27.0] μm), than in BK (13.0 [12.0; 14.0] μm). Morphological study of EDM and corneal buttons showed similar difference in DM thickness: 17.9 [16.1; 20.0] μm in FECD and 11.9 [11.3; 13.0] μm in BK. Irregular optical density of stroma is a feature of edema and local fibrosis. In FECD and BK pancytokeratin is expressed in epithelial and endothelial cells, vimentin - in keratocytes, macrophages and vascular endothelium, fibronectin - in DM. In FECD, vimentin is expressed in endothelial cells.

Conclusion: FECD and BK are associated with different DM' and endothelium' abnormalities, which lead to similar changes of stroma and epithelium. AS-OCT is a useful method of FECD and BK in vivo diagnostics and the selection of treatment option.

Download full-text PDF

Source
http://dx.doi.org/10.17116/patol20238505129DOI Listing

Publication Analysis

Top Keywords

fuchs endothelial
8
endothelial corneal
8
corneal dystrophy
8
fecd
8
group patients
8
patients eyes
8
corneal buttons
8
[corneal changes
4
changes fuchs
4
endothelial
4

Similar Publications

Predicting corneal decompensation in Fuchs endothelial corneal dystrophy with Scheimpflug tomography and clinical parameters.

Indian J Ophthalmol

January 2025

Department of Ophthalmology, Université Paris Cité, Cochin Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France.

Purpose: This study aims to evaluate the efficacy of various tomographic indices, both established and novel, in predicting endothelial decompensation leading to either spontaneous corneal transplantation or transplantation following cataract surgery in patients with Fuchs endothelial corneal dystrophy (FECD).

Methods: In this cross-sectional, retrospective study, we reviewed the files of 93 eyes from 54 FECD patients undergoing regular follow-up. We recorded clinical metrics such as morning visual disturbance (MVD) and corrected distance visual acuity.

View Article and Find Full Text PDF

Objective: An intronic cytosine-thymine-guanine (CTG) triplet repeat expansion in the transcription factor 4 gene () gene (CTG18.1) confers significant risk for the development of Fuchs' endothelial corneal dystrophy (FECD). The objective of this study was to conduct an unbiased survey of the CTG18.

View Article and Find Full Text PDF

Quality of Life Survey Using NEI VFQ-25 in Japanese Patients With Fuchs Endothelial Corneal Dystrophy.

Eye Contact Lens

December 2024

Department of Ophthalmology (K.Y., Y.O., N.N., S.M., C.K., M.K., Reiko Kobayashi, T.S., S.K., K.N.), Osaka University Graduate School of Medicine, Suita, Osaka, Japan; and Division of Public Health (Ryo Kawasaki), Department of Social Medicine, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.

Objectives: To assess the quality of life in Japanese patients with Fuchs endothelial corneal dystrophy (FECD) using The National Eye Institute Visual Function Questionnaire.

Methods: Here, 34 patients with FECD (FECD group) and 13 healthy individuals (control group) completed the National Eye Institute Visual Function Questionnaire Japanese version by interview format. The association between dominant eye corrected distance visual acuity and composite score (component 11) or subscales in the FECD group was evaluated using Spearman rank correlation coefficient.

View Article and Find Full Text PDF

Assessing Corneal Tomographic Changes in Fuchs Endothelial Corneal Dystrophy Over 1 year: Scheimpflug Versus Anterior Segment Optical Coherence Tomography.

Cornea

December 2024

Ophthalmology Biology, Engineering and Imaging Laboratory, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France.

Purpose: The objective of this study was to compare the capacity of anterior segment optical coherence tomography (AS-OCT) and Scheimpflug camera in detecting tomographic changes over 1 year in a cohort of patients with Fuchs endothelial corneal dystrophy.

Methods: We conducted a single-center prospective study which consisted of 2 identical visits spaced 1 year apart. At each visit, tomographic analyses were performed using Scheimpflug imaging (Pentacam HR, Oculus) and swept source AS-OCT (Casia SS-1000 Tomey).

View Article and Find Full Text PDF
Article Synopsis
  • Over the past 40 years, around 40,000 Australians have undergone corneal transplants, primarily due to conditions like keratoconus and Fuchs' dystrophy, with increasing demand due to an aging population.
  • The global shortage of donor corneas is significant, with demand exceeding supply by 70 times, particularly in less-developed countries, prompting advancements in tissue banking and surgical techniques.
  • New strategies like organ culture for donor corneas, bespoke surgical methods, and cell culture technologies are improving tissue storage, reducing transplant requirements, and enhancing patient care for corneal conditions.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!