Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background Advances in imaging techniques have led to increased utilization of imaging devices in catheterization laboratories. Invasive surgical procedures for cardiac disorders have been largely replaced by fluoroscopic cardiac catheterization. With this increase, concerns and risks associated with exposure to ionizing radiation among interventional cardiologists are growing. This study aims to measure and compare the occupational doses to the eye lens and thyroid of pediatric interventional cardiologists during different procedures in the catheterization laboratory and its significance. Methodology In this study, cardiologists wore bandanas with attached dosimeters to measure the absorbed doses to the eyes and thyroid gland. The dosimeters were collected for reading. The procedure types were also collected. In addition, the total fluoroscopy time and tube voltage of the biplane machine were measured. SPSS version 23 (IBM Corp., Armonk, NY, USA) was used to analyze the data. The characteristics of the study sample were described using simple counts and percentages, whereas means and standard deviations were used for continuous variables. Statistical significance was set at p-values <0.05. Results A total of 93 procedures were evaluated. The mean absorbed doses for all 93 procedures in both eyes and thyroid were 0.09 mGy and 0.08 mGy, respectively. A significant difference was found between the left and right eye measurements (p = 0.034), with higher doses administered to the left eye. However, no significant difference was observed between the right and left thyroid doses (p = 0.281). Significant correlations were found between the eye and thyroid doses and the procedure type (p = 0.02 and p = 0.009, respectively). Conclusions A significant amount of radiation was measured in the measurements of both organs. In addition, radiation dose measurements varied between different types of procedures. Our current results indicate the importance and necessity of applying the radiation protection concept of dose optimization.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10560443 | PMC |
http://dx.doi.org/10.7759/cureus.44894 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!