Evaluative audiometry after cochlear implant provision.

HNO

Cochlear Deutschland GmbH & Co. KG, Hannover, Germany.

Published: January 2024

AI Article Synopsis

Article Abstract

Background: One of the main treatment goals in cochlear implant (CI) patients is to improve speech perception. One of the target parameters is speech intelligibility in quiet. However, treatment results show a high variability, which has not been sufficiently explained so far. The aim of this noninterventional retrospective study was to elucidate this variability using a selected population of patients in whom etiology was not expected to have a negative impact on postoperative speech intelligibility.

Materials And Methods: Audiometric findings of the CI follow-up of 28 adult patients after 6 months of CI experience were evaluated. These were related to the preoperative audiometric examination and evaluated with respect to a recently published predictive model for the postoperative monosyllabic score.

Results: Inclusion of postoperative categorical loudness scaling and hearing loss for Freiburg numbers in the model explained 55% of the variability in fitting outcomes with respect to monosyllabic word recognition.

Conclusion: The results of this study suggest that much of the cause of variability in fitting outcomes can be captured by systematic postoperative audiometric checks. Immediate conclusions for CI system fitting adjustments may be drawn from these results. However, the extent to which these are accepted by individual patients and thus lead to an improvement in outcome must be subject of further studies, preferably prospective.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10799098PMC
http://dx.doi.org/10.1007/s00106-023-01317-7DOI Listing

Publication Analysis

Top Keywords

cochlear implant
8
variability fitting
8
fitting outcomes
8
evaluative audiometry
4
audiometry cochlear
4
implant provision
4
provision background
4
background main
4
main treatment
4
treatment goals
4

Similar Publications

EXPRESS: The Time Course of Cognitive Effort During Disrupted Speech.

Q J Exp Psychol (Hove)

January 2025

Hearing Aid Laboratory, Northwestern University, Department of Communication Sciences and Disorders Evanston, IL, USA.

Listeners often find themselves in scenarios where speech is disrupted, misperceived, or otherwise difficult to recognize. In these situations, many individuals report exerting additional effort to understand speech, even when repairing speech may be difficult or impossible. This investigation aimed to characterize cognitive effort across time during both sentence listening and a post-sentence retention interval by observing the pupillary response of participants with normal to borderline normal hearing in response to two interrupted speech conditions: sentences interrupted by gaps of silence or bursts of noise.

View Article and Find Full Text PDF

Background: Electrically evoked compound action potential (ECAP) can be used to measure the auditory nerve's response to electrical stimulation in cochlear implant (CI) users. In the Nurotron CI system, extracting the ECAP waveform from the stimulus artifact is time-consuming.

Method: We developed a new paradigm ("FastCAP") for use with Nurotron CI devices.

View Article and Find Full Text PDF

Can a Cochlear Implant Be Used as an Electrical Impedance Tomography Device?

Int J Numer Method Biomed Eng

January 2025

Bioengineering, Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Gauteng, South Africa.

The imaging of the live cochlea is a challenging task. Regardless of the quality of images obtained from modern clinical imaging techniques, the internal structures of the cochlea mainly remain obscured. Electrical impedance tomography (EIT) is a safe, low-cost alternative medical imaging technique with applications in various clinical scenarios.

View Article and Find Full Text PDF

Objective: To provide evidence to use an extended frequency pure tone average to screen for cochlear implant evaluation candidates as recommended by the American Cochlear Implant Alliance. Additionally, to determine whether traditional low frequency, high or low frequency, high frequency, or extended frequency pure tone average most accurately predicts cochlear implant candidates based on speech perception scores from aided AzBio sentence testing or aided consonant-nucleus-consonant (CNC) testing.

Method: Adults from a tertiary care center who completed aided sentence testing during cochlear implant evaluation between 2014 and 2024 were assessed.

View Article and Find Full Text PDF

Background: The intraoperative measurements are essential steps in cochlear implant (CI) surgery for confirming correct electrode placement.

Objectives: To examine the intraoperative impedance and electrically evoked action potential (ECAP) measurement results of cochlear implant (CI) users with normal cochlear anatomy (NCA) and to compare them with CI users with inner ear malformations (IEM).

Material And Methods: This retrospective study included intraoperative data of 300 ears from 258 individuals using Medel and Cochlear (Nucleus) CI devices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!