In this study, a simple, inexpensive, selective, and fast salting-out assisted liquid-liquid extraction (SALLE) technique coupled with high-pressure liquid chromatography-diode array detection (HPLC-DAD) was developed for the extraction, preconcentration, and analysis of trace level seven multiclass pesticide residues in pasteurized and raw cow milk samples. The significant factors that affect the extent to which the target analytes are extracted, such as the type of extraction solvent and its volume, the type and concentration of salting-out salts, the pH of the solution, and the extraction time, have been investigated. Under optimum conditions, the correlation coefficient () was obtained within a range of 0.9982-0.9997 for a broad linear range concentration of 2-1500 ng·mL. Reliable sensitivity was achieved with limits of detection (LODs) and limits of quantification (LOQs) ranging from 0.58-2.56 ng·mL and 1.95-8.51 ng·mL, respectively. While precision with interday and intraday in terms of relative standard deviations (RSDs) was observed in the range of 1.97 - 7.88% and 4.52 - 8.04%, respectively. The results of the precision studies reveal that good repeatability and reproducibility (RSDs <9) were achieved, thus showing a low variability extraction of the developed method. Finally, the proposed and validated approach was effectively used to extract and determine pesticide residues in real milk matrices; however, the target analytes were not detected in all samples.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558272PMC
http://dx.doi.org/10.1155/2023/1754956DOI Listing

Publication Analysis

Top Keywords

liquid-liquid extraction
8
multiclass pesticide
8
pesticide residues
8
cow milk
8
extraction
5
highly selective
4
selective analytical
4
analytical method
4
method based
4
based salt-assisted
4

Similar Publications

In this research, a green approach utilizing deep eutectic solvent liquid-liquid microextraction is combined with smartphone digital image colorimetry for the determination of boron in nut samples. A smartphone camera was used to capture the image of the analyte extract located in a custom-made colorimetric box. Using ImageJ software, the images were split into RGB channels, with the green channel identified as the optimum.

View Article and Find Full Text PDF

In the present research, an attempt has been made to develop a new thin film microextraction method for the extraction of several polycyclic aromatic hydrocarbons from aqueous samples collected from different industrial units prior to their analysis by gas chromatography combined with a flame ionization detector. In this approach, a thin iron mesh was modified by the formation of iron(II) oxinate on its surface and used for the extraction of analytes without an additional sorbent. For this purpose, first, the mesh was immersed in a sulfuric acid solution and then transferred into an 8-hydroxy quinoline (oxine) solution dissolved in ammonia solution.

View Article and Find Full Text PDF

Bu Shen Jian Gu Oral Liquid (BSJG) is a hospital formulation commonly utilized in the treatment of fractures, joint dislocations, and rheumatoid arthritis. However, there has been no effective and straightforward method to comprehensively assess the quality of BSJG. In this experiment, a fingerprint of various batches of BSJG was established using high-performance liquid chromatography (HPLC).

View Article and Find Full Text PDF

Natural deep eutectic solvent-based liquid phase microextraction in a 3D-Printed millifluidic flow cell for the on-line determination of thiabendazole in juice samples.

Anal Chim Acta

February 2025

Departamento de Medio Ambiente y Agronomía, INIA-CSIC, Carretera de A Coruña km. 7.5, 28040, Madrid, Spain. Electronic address:

Background: At present, 3D printing technology is becoming increasingly popular in analytical chemistry because it enables the rapid and cost-effective manufacture of sample preparation devices, particularly in flow-based operation, opening up new opportunities for the development of automated analytical methods. In parallel, the use of miniaturized methods and sustainable solvents in sample preparation is highly recommended. Accordingly, in this work, a 3D-printed millifluidic device was designed and used for the on-line natural deep eutectic solvent (NADES)-based liquid phase microextraction (LPME) coupled to a spectrofluorometer for, as a proof of concept, the determination of thiabendazole (TBZ) in fruit juice samples.

View Article and Find Full Text PDF

Background: The demand for sustainable energy solutions has increased interest in natural microalgal dyes as photosensitizers in dye-sensitized solar cells (DSSCs). This study addresses the critical issue of maximizing dye integrity and yield during extraction, particularly the degradation that occurs at temperatures above 60 °C. Our investigation of dye extraction from Asterarcys quadricellulare and Scenedesmus sp.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!