An in-syringe low-density solvent dispersive liquid-liquid microextraction (IS-LDS-DLLME) is presented for the extraction of palladium from a highly acidic medium before its quantification by inductively coupled plasma optical emission spectroscopy. The extraction solvent was 1-undecanol, and benzil mono-(2-pyridyl) hydrazone was employed as a ligand. Here, no dispersive solvent is needed as the vortex disperses 1-undecanol in the aqueous sample solution. The experimental variables pH, concentration of the ligand, type and quantity of the extraction solvent, vortex time, and addition of NaCl were optimized. The described approach has detection and quantification limits of 0.13 and 0.43 μg L, respectively, an enrichment factor of 91, a linear analytical range from 0.4 to 250 μg L, and a precision of 1.7-2.0 % (25.0 μg L). The approach was used to analyze electronic waste samples and certified reference material.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.saa.2023.123462 | DOI Listing |
Spectrochim Acta A Mol Biomol Spectrosc
January 2024
Chemistry Department, Industrial Education College, Beni-Suef University, Beni-Suef, Egypt.
An in-syringe low-density solvent dispersive liquid-liquid microextraction (IS-LDS-DLLME) is presented for the extraction of palladium from a highly acidic medium before its quantification by inductively coupled plasma optical emission spectroscopy. The extraction solvent was 1-undecanol, and benzil mono-(2-pyridyl) hydrazone was employed as a ligand. Here, no dispersive solvent is needed as the vortex disperses 1-undecanol in the aqueous sample solution.
View Article and Find Full Text PDFJ Sep Sci
October 2022
Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
In the current study, a combination of microwave-assisted solvent extraction combined with effervescence-assisted deep eutectic solvent-based in-syringe dispersive liquid-liquid microextraction has been developed as a new sample pretreatment method. The offered method was used for the extraction of five triazine pesticides (atrazine, propazine, cyanazine, ametryn, and simazine) from apple samples before their determination by gas chromatography-flame ionization detection. For this purpose, briefly, the apple sample was contacted with a suitable acidified extraction solvent and the mixture was exposed to microwave irradiations.
View Article and Find Full Text PDFTalanta
September 2022
Sciware Systems, S.L. 07193, Bunyola, Spain. Electronic address:
A lab-in-syringe flow system exploiting dispersive liquid-liquid micro-extraction in a solvent lighter than water is proposed for the spectrophotometric determination of lead in industrial residual waters. The steps inherent to both liquid-liquid extraction and monitoring of the formed compound are in-syringe carried out. The classical carbon tetrachloride is not used as the extracting solvent, as it does not present the friendly characteristics inherent to the Green Analytical Chemistry.
View Article and Find Full Text PDFJ Pharm Biomed Anal
February 2022
Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran. Electronic address:
A new sample preparation method named in-syringe gas-assisted density tunable dispersive liquid phase microextraction based on solidification of floating organic droplet has been introduced. This method was coupled with high-performance liquid chromatography-tandem mass spectrometry and used for the extraction and quantification of amikacin in plasma and exhaled breath condensate (EBC) samples of the patients receiving amikacin. In the proposed approach, an inert gas is bubbled into a syringe barrel containing aqueous solution of the analyte and a mixture of low density extraction solvent and volatile density modifier.
View Article and Find Full Text PDFJ Sep Sci
August 2021
Department of Occupational Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran.
trans,trans-Muconic acid has been widely used as a biomarker in biological monitoring of benzene-exposed workers during routine occupational health services. In the present study, a novel microextraction technique, in-syringe ionic liquid-dispersive liquid-liquid microextraction, was implemented for preconcentration of trans,trans-muconic acid followed by analytical determination by high-performance liquid chromatography with ultraviolet detection. Moreover, the important variables affecting the performance of applied microextraction technique including needle diameter, volume of the spiked sample, volume of the ionic liquid, salt addition, rotation speed of centrifugation, centrifuge time, and ultrasonic time were optimized by experimental design.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!