Background: This study aims to identify the relationship between iris -ciliary angle (ICA) and the vault. Additionally, we also seek to investigate the chain mediating effects of the ICL haptic related factors on this relationship.

Methods: The participants were categorized into three groups according to the ICA value as follows: low ICA group (< 35°); moderate ICA group (35°-70°); high ICA group (> 70°). We compared the preoperative ocular characteristics and postoperative examinations among the three groups. Multiple variable stepwise regression was performed to establish the vault prediction formula. The Process V4.0 in SPSS and Hayes's PROCESS model 6 was conducted to further elucidate the mediating effects of the final tip point of ICL haptic and the ICL arc-lens arc on the relationship between the ICA and vault.

Results: There was a significant difference in the positions of the ICL haptic among three ICA groups. The regression vault equation was Vault = 679.42-7.26*TCA + 192.30*ACD-196.37*CLR + 73.21* STS(horizontal).A significant negative correlation was found between the ICA and vault (P < 0.01).The chain mediation model revealed that the final tip point of ICL haptic and the ICL arc-Lens arc were sequential mediators between ICA and vault (effect = -1.63, 95% CI = -2.72--0.73).

Conclusion: The ICA was associated with vault via the mediation effect of the final tip point of the ICL haptic and the ICL arc -lens arc. Assessment of ICL haptic related parameters adds significant information to interpret the vault after surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10559582PMC
http://dx.doi.org/10.1186/s12886-023-03122-wDOI Listing

Publication Analysis

Top Keywords

icl haptic
16
ica vault
12
iris -ciliary
8
-ciliary angle
8
angle ica
8
haptic factors
8
mediating effects
8
three groups
8
ica
7
vault
5

Similar Publications

Purpose: To evaluate dynamic changes in ciliary parameters and Implantable Collamer Lens V4C (ICL) (STAAR Surgical) haptic position using mydriatic and miotic agents and their effects on the central and peripheral vault.

Methods: This study involved 80 eyes from 40 consecutive patients (mean age: 28.05 years; range: 19 to 42 years) examined 3 months after ICL implantation.

View Article and Find Full Text PDF

Clinical observations of EVO-ICL implantation with single incision without viscoelastic agent.

BMC Ophthalmol

August 2024

Beijing Tongren Hospital, Beijing Tongren Eye Center, Capital Medical University, Beijing, 100730, China.

Background: To investigate the safety and effectiveness of non-viscoelastic agent technique for EVO-ICL implantation.

Methods: A total of 181 myopia eyes that underwent non-toric ICL without viscoelastic agent through single incision from Beijing Tongren Hosipital were included. An analysis was conducted on the quantity of haptics that were initially implanted intraoperatively into the posterior chamber.

View Article and Find Full Text PDF

Effect of anterior segment structure on vault and position after implantable collamer lens implantation.

Indian J Ophthalmol

September 2024

Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, No. 77, Daping Changjiang Second Road, Yuzhong, 400040, Chongqing, China.

Purpose: To evaluate the effect of anterior-segment structure on vault and position after implantable collamer lens (ICL) implantation using ultrasound biomicroscopy.

Methods: The retrospective case-control study included insufficient vault eyes (<250 µm), ideal vault eyes (250-750 µm), and excessive vault eyes (>750 µm). The preoperative biometric parameters of the anterior-segment structure and basic data between the three groups were analyzed using one-way analysis of variance.

View Article and Find Full Text PDF

To report the first case of uveitis-glaucoma-hyphema (UGH) syndrome post implantable collamer lens (ICL). Case report A 41-year-old female presented to our clinic complaining of bilateral eye pain and redness for two weeks. Her past medical history was significant for ICL, in both eyes and multiple sclerosis controlled with treatment.

View Article and Find Full Text PDF

We describe and assess the efficiency of a novel technique of placing implantable collamer lens (ICL) footplates in the sulcus in poorly dilated pupils utilizing perioptic holes and two instruments simultaneously (Sinskey hook and ICL manipulator). Twelve eyes of 10 patients underwent ICL implantation through this technique. The technique employs a bimanual approach engaging perioptic holes in the eyes with intraoperative miosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!