A simple and rapid method for detecting fecal pollution in urban rivers by measuring the intrinsic β-D-glucuronidase activity of Escherichia coli.

Water Res

Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, North-13, West-8, Sapporo 060-8628, Japan. Electronic address:

Published: November 2023

As urban rivers are domestic, industrial, and agricultural water resources, fecal pollution poses human health and environmental risks. In this study, we developed a simple and rapid method to detect fecal pollution in urban rivers. Water samples were mixed with liquid medium, including a fluorescent substrate and fluorescence intensity (F.I.) was measured using a microplate reader to determine Escherichia coli (E. coli) β-D-glucuronidase (GUS) activity instead of E. coli concentration. GUS activities measurements in pure E. coli cultures revealed that E. coli incubated with a GUS substrate accumulated GUS enzymes in their cells, whereas those incubated without a GUS substrate did not. The increase in GUS activity corresponded to the proliferation of E. coli and the GUS activity increased linearly even during the lag growth phase of E. coli, indicating the presence of intrinsic GUS (iGUS) in E. coli cells before incubation. iGUS activity persisted at 81 % in the chlorinated samples, even though the E. coli concentration was reduced by a factor of 10. The iGUS activity persisted for approximately three days. Therefore, we assumed that E. coli present in fecal contaminants, in which GUS substrates are present, could be distinguished from those surviving in the natural environment for three days or longer by measuring iGUS activity. River water samples were collected upstream and downstream of the discharge outlets of municipal wastewater treatment plants and a combined sewer outlet. The iGUS activities were <0.24 mMFU/mL for the upstream samples and >0.21 mMFU/mL for the downstream samples. Interestingly, E. coli concentrations were not necessarily associated with fecal pollution. This indicates that by setting a threshold for iGUS activity, our method can be used as a simple and rapid method for detecting fecal pollution in urban rivers. Because the limit of detection for our method is 20 CFU/mL, our method is applicable to detecting high fecal pollution in a small river.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2023.120689DOI Listing

Publication Analysis

Top Keywords

fecal pollution
24
urban rivers
16
igus activity
16
simple rapid
12
rapid method
12
pollution urban
12
coli
12
gus activity
12
gus
9
method detecting
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!