Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Streptococcus suis (S. suis) is a major pig pathogen worldwide with zoonotic potential. Though different research groups have contributed to a better understanding of the pathogenesis of S. suis infections in recent years, there are still numerous neglected research topics requiring animal infection trials. Of note, animal experiments are crucial to develop a cross-protective vaccine which is highly needed in the field. Due to the severe clinical signs associated with S. suis pathologies such as meningitis and arthritis, implementation of refinement is very important to reduce pain and distress of experimentally infected pigs. This review highlights the great diversity of clinical signs and courses of disease after experimental S. suis pig infections. We review clinical read out parameters and refinement strategies in experimental S. suis pig infections published between 2000 and 2021. Currently, substantial differences exist in describing clinical monitoring and humane endpoints. Most of the reviewed studies set the body temperature threshold of fever as high as 40.5°C. Monitoring intervals vary mainly between daily, twice a day and three times a day. Only a few studies apply scoring systems. Published scoring systems are inconsistent in their inclusion of parameters such as body temperature, feeding behavior, and respiratory signs. Locomotion and central nervous system signs are more common clinical scoring parameters in different studies by various research groups. As the heterogenicity in clinical monitoring limits the comparability between studies we hope to initiate a discussion with this review leading to an agreement on clinical read out parameters and monitoring intervals among S. suis research groups.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10552360 | PMC |
http://dx.doi.org/10.1186/s12917-023-03735-9 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!