A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance evaluation of Biofire Film Array Respiratory Panel 2.1 for SARS-CoV-2 detection in a pediatric hospital setting. | LitMetric

The highly contagious nature of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of Coronavirus Disease 2019 (COVID-19), requires rapid diagnostic tests to prevent the virus from spreading within hospitals and communities. Reverse transcription followed by the polymerase chain reaction (RT-PCR) test is the gold standard for detecting SARS-CoV-2 infections but is time-consuming, labor-intensive, and restricted to centralized laboratories. There is a growing need to develop and implement point-of-care and rapid tests for SARS-CoV-2 detection to address these limitations. We aimed to evaluate the performance of BioFire Film Array Respiratory Panel 2.1 (BioFire FA-RP2.1) for SARS-CoV-2 detection in a pediatric hospital setting. The BioFire FA-RP2.1 test provides rapid results and can identify several viral and bacterial infections in a single test. This prospective, cross-sectional, diagnostic accuracy study enrolled participants ranging from 0 to 18 years of age, seeking medical consultation for any reason, who had been in contact with individuals confirmed to have COVID-19 or managed at the hospital for medical or surgical reasons. We employed a systematic sampling technique to ensure a representative sample. The study included 339 participants with a median age of 5 years. The BioFire FA-RP2.1 test detected SARS-CoV-2 in 18.6% of cases, while the reference RT-PCR test in 14% of cases. The BioFire FA-RP2.1 sensitivity and specificity for SARS CoV-2 detection were 98% and 94%, respectively. The positive probability coefficient (LR+) was 18. The agreement between the two tests was 0.80. In addition, the BioFire FA-RP2.1 test detected coinfection with two viruses in 7,6% of cases. The BioFire FA-RP2.1 is a reliable solution to meet pediatric healthcare needs and improve prognosis in the post-pandemic era thanks to its friendly interface and rapid testing process.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10553804PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0292314PLOS

Publication Analysis

Top Keywords

biofire fa-rp21
24
sars-cov-2 detection
12
fa-rp21 test
12
biofire
8
biofire film
8
film array
8
array respiratory
8
respiratory panel
8
detection pediatric
8
pediatric hospital
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!