Background: The study was to evaluate the effectiveness of dose distribution of four-dimensional computed tomography (4DCT) simulation.

Materials And Methods: The gross tumor volume (GTV) and clinical target volume (CTV) were contoured in all 10 respiratory phases of 4DCT in 30 patients with non-small cell lung cancer (NSCLC). Both 3D and 4D treatment plans were made individually for each patient using the planning volume (PTV). The PTV3D was taken from a single CTV plus the recommended margin, and the PTV4D was taken from the 4D internal target volume, including all 10 CTVs plus the setup margins.

Results: The mean PTV was 460 ± 179 (69-820) cm for 3DCT and 401 ± 167 (127-854) cm for 4DCT (p = 0.0018). The dose distribution (DD) of organs at risk, especially the lungs, was lower for the 4DCT simulation. The V5%, V10%, and V20% of the total lung dose for 4DCT were significantly lower for the 3DCT. However, lung V30% the heart, esophagus, and spinal cord were not significantly different. In addition, the conformity index and the dose heterogeneity index of the PTV were not significantly different. The normal tissue complication probability (NTCP) of the lung and heart was significantly lower for 4DCT than for 3DCT.

Conclusions: The 4DCT simulation gives better results on the NTCP. The organs at risk, especially the lungs, receive a significantly lower DD compared with the 3DCT. The conformity index (CI), heterogeneity index (HI) and the DD to the heart, spinal cord, and esophagus were not significantly different between the two techniques.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10547414PMC
http://dx.doi.org/10.5603/RPOR.a2023.0056DOI Listing

Publication Analysis

Top Keywords

4dct
8
dose distribution
8
target volume
8
organs risk
8
risk lungs
8
lower 4dct
8
4dct simulation
8
spinal cord
8
institutional experience
4
experience implementing
4

Similar Publications

This study was conducted to evaluate the use of 4-dimensional (4D) maximum intensity projection (4D-MIP) to compensate for the disadvantages of average intensity projection (AIP), which is used to determine the internal target volume (ITV) in lung tumors. A respiratory motion phantom with a simulated tumor was imaged using 4D computed tomography (4D-CT). AIP and 4D-MIP were generated based on 10 phases of 4D-CT, followed by contouring of the ITV and ITV; these were compared with the ITV contoured in 10 phases of 4D-CT (ITV).

View Article and Find Full Text PDF

Real-time lung extraction from synthesized x-rays improves pulmonary image-guided radiotherapy.

Phys Med Biol

January 2025

Radiation Oncology, University of California San Francisco, 1600 Divisadero St, San Francisco, California, 94143, UNITED STATES.

Lung tumors can be obscured in X-rays, preventing accurate and robust localization. To improve lung conspicuity for image-guided procedures, we isolate the lungs in the anterior-posterior (AP) X-rays using a lung extraction network (LeX-net) that virtually removes overlapping thoracic structures, including ribs, diaphragm, liver, heart, and trachea. Approach: 73,965 thoracic 3DCTs and 106 thoracic 4DCTs were included.

View Article and Find Full Text PDF

Purpose: This observational pilot study investigated (1) carpal positioning in the neutral wrist pose, (2) the scapholunate (SL) rotation axis, (3) physiological SL motion, and (4) the SL distance after combined palmar and dorsal SL ligament reconstruction using quantitative four-dimensional computed tomography (4D-CT) imaging.

Methods: Six subjects were included, and 4D-CT images of both wrists were obtained. Kinematic parameters of the treated side were compared to those of the healthy contralateral side, which was used as the normal reference.

View Article and Find Full Text PDF

Objective: The aim of the study is to assess the diagnostic accuracy of 4-dimensional computed tomography (4D-CT) scans for patients with primary hyperparathyroidism (pHPT) after negative or inconclusive Technetium-99m sestamibi single-photon emission computed tomography scan.

Methods: A literature search of several databases was conducted from inception to August 2023. Eligible studies reported adult patients (>18 years old) who underwent 4D-CT after negative or inconclusive sestamibi results.

View Article and Find Full Text PDF

Localization in primary hyperparathyroidism.

Best Pract Res Clin Endocrinol Metab

December 2024

Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Sector 12, Chandigarh 160012, India. Electronic address:

Primary hyperparathyroidism is the main cause of hypercalcemia, resulting predominantly from parathyroid adenomas followed by hyperplasia. Diagnosis relies on clinical and biochemical parameters. Accurate pre-operative localization is mandatory for better surgical outcome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!