A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Isodose surface differences: A novel tool for the comparison of dose distributions. | LitMetric

Isodose surface differences: A novel tool for the comparison of dose distributions.

J Appl Clin Med Phys

2nd Department of Radiology, University General Hospital "Attikon", 1 Rimini Street, National and Kapodistrian University of Athens, Chaidari, Greece.

Published: November 2023

Background: Comparing dose distributions is a routine task in radiotherapy, mainly in patient-specific quality assurance (PSQA). Currently, the evaluation of the dose distributions is being performed mainly with statistical methods, which could underestimate the clinical importance of the spotted differences, as per the literature.

Purpose: This paper aims to provide proof-of-concept for a novel dose distribution comparison method based on the difference of the isodose surfaces. The new method connects acceptance tolerance to QA limitations (equipment capabilities) and integrates a clinical approach into the analysis procedure.

Methods: The distance of dose points from the isocenter can be used as a function to define the shape of an isodose surface expressed as a histogram. Isodose surface differences (ISD) are defined as the normalized differences of reference and evaluated surface histograms plotted against their corresponding isodose. Acceptance tolerances originate from actual QA tolerances and are presented clinically intuitively. The ISD method was compared to the gamma index using intentionally erroneous VMAT and IMRT plans.

Results: Results revealed that the ISD method is sensitive to all errors induced in the plans. Discrepancies are presented per isodose, enabling the evaluation of the plan in two regions representing PTV and Normal Tissue. ISD manages to flag errors that would remain undetected under the gamma analysis.

Conclusion: The ISD method is a meaningful, QA-related, registration-free, and clinically oriented technique of dose distribution evaluation. This method can be used either as a standalone or an auxiliary tool to the well-established evaluation procedures, overcoming significant limitations reported in the literature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10647989PMC
http://dx.doi.org/10.1002/acm2.14085DOI Listing

Publication Analysis

Top Keywords

isodose surface
12
dose distributions
12
isd method
12
surface differences
8
dose distribution
8
isodose
6
dose
6
method
6
differences
4
differences novel
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!