A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Difference in target dose distributions between Acuros XB and collapsed cone convolution/superposition and the impact of the tumor locations in clinical cases of stereotactic ablative body radiotherapy for lung cancer. | LitMetric

Objectives: The objective of the study is to analyze the difference in target dose distributions between Acuros XB (AXB) and collapsed cone convolution (CCC)/superposition and the impact of the tumor locations in clinical cases of stereotactic ablative body radiotherapy (SABR) for lung cancer.

Materials And Methods: Ninety-six patients underwent SABR for lung cancers Kyushu University Hospital from 2014 to 2017. We recalculated clinical plans originally calculated by AXB using CCC with the identical monitor units (MUs) and beam arrangements. We calculated the following dosimetric parameters: maximum dose (Dmax), minimum dose (Dmin), homogeneity index (HI), conformity index (CI), and D95 of the planning target volume (PTV). We investigated the difference between the results of two calculations and examined the impact of tumor location. Moreover, we determined the target central dose using a thorax phantom and assessed the calculation accuracy of the two algorithms for each fraction.

Results: CCC significantly overestimated the dose to PTV, compared to AXB (P < 0.05). The mean differences of Dmax, Dmin, and D95 were 1.17, 1.95, and 1.85 Gy, respectively. The mean differences of HI and CI were 0.02 and - 0.06. Dmin, HI, and D95 had significant correlations with the tumor location, and the difference was greater when the PTV was included the chest wall (P < 0.05). The discrepancy between the calculated and irradiated dose was 2.48% for CCC, whereas it was 0.14% for AXB.

Conclusions: We demonstrated that CCC significantly overestimated the dose to PTV relative to AXB in clinical cases of lung SABR.

Download full-text PDF

Source
http://dx.doi.org/10.4103/jcrt.jcrt_1740_21DOI Listing

Publication Analysis

Top Keywords

impact tumor
12
clinical cases
12
difference target
8
dose
8
target dose
8
dose distributions
8
distributions acuros
8
collapsed cone
8
tumor locations
8
locations clinical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!