Objectives: The aim of this in vitro study was to evaluate the effect of a 3D-printed drill sleeve (DS) on the precision and duration of coronectomy sections.
Materials And Methods: Thirty-six trainees and oral surgeons performed 72 coronectomy cuts in a 3D-printed, entirely symmetric mandible model. Coronectomy was performed freehand (FH) on one side and with a DS on the other side. The occurrence of "too superficial" (≥ 4 mm unprepared lingual tooth tissue) and "too deep" (drilling ≥ 1 mm deeper as tooth contour) cuts and sectioning times were registered.
Results: In 7 cases, the sections were "too deep" with FH, while none with DS (OR: 18.56; 95%CI: 1.02-338.5; p = 0.048). The deviation between virtually planned and real cut depths was significantly greater in the FH group (1.91 ± 1.62 mm) than in DS group (1.21 ± 0.72 mm) (p < 0.001). A total of 18 "too superficial" buccolingual sections occurred with FH, while 8 cases with DS (OR: 3.50; 95%CI: 1.26-9.72; p = 0.016). Suboptimal sections did not correlate with experience (p = 0.983; p = 0.697). Shortest, suboptimal drillings were most frequently seen distolingually (OR: 6.76; 95% CI: 1.57-29.07; p = 0.01). In the inexperienced group, sectioning time was significantly longer with FH (158.95 ± 125.61 s vs. 106.92 ± 100.79 s; p = 0.038).
Conclusions: The DS effectively reduced tooth sectioning times by less experienced colleagues. Independently from the level of experience, the use of DS obviated the need for any preparation outside the lingual tooth contour and significantly decreased the occurrence of "too superficial" cuts, leaving thinner unprepared residual tooth tissue lingually.
Clinical Relevance: Coronectomy sections may result in lingual hard and soft tissue injury with the possibility of damaging the lingual nerve. The precision of the buccolingual depth-control can be improved, while surgical time can be reduced when applying a drilling sleeve.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10630220 | PMC |
http://dx.doi.org/10.1007/s00784-023-05289-4 | DOI Listing |
Arthroscopy
January 2025
Kansas City Orthopedic Alliance, 10777 Nall Avenue, Overland Park, KS 66224. Electronic address:
As surgeons, we strive to recognize and correct any mistakes that may occur before completing an operation, and importantly, do our best to avoid irreversible mistakes. Over-resection of the femoral cam lesion in patients having hip arthroscopy for femoroacetabular impingement syndrome has been considered irreversible. While cam under-resection is a technical complication of femoroacetabular impingement surgery to be avoided, avoiding this at the expense of over-resection of the proximal femur is of great concern.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Faculty of Civil and Transport Engineering, Institute of Machines and Motor Vehicles, Poznan University of Technology, 60-965 Poznan, Poland.
In the study of structural materials, the analysis of fracture and deformation resistance plays an important role, particularly in materials widely used in the construction industry, such as poly(vinyl chloride) (PVC). PVC is a popular material used, among others, in the manufacture of window profiles, doors, pipes, and many other structural components. The aim of this research was to define the influence of the degree of milling of the glass-fibre-reinforced composite on the strength of the window frame welds, and in the next step, to propose new welding parameters to obtain sufficient strength properties that allow reducing the cost of the technological welding operation.
View Article and Find Full Text PDFMed Image Anal
December 2024
School of Computer Science and Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
Continual test-time adaptation (CTTA) aims to continuously adapt a source-trained model to a target domain with minimal performance loss while assuming no access to the source data. Typically, source models are trained with empirical risk minimization (ERM) and assumed to perform reasonably on the target domain to allow for further adaptation. However, ERM-trained models often fail to perform adequately on a severely drifted target domain, resulting in unsatisfactory adaptation results.
View Article and Find Full Text PDFBMC Med Educ
November 2024
Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany.
Background: This in vitro study investigated whether full-guided (FG) or half-guided (HG) implant placement is more suitable for beginners and to what extent the use of the coDiagnostiX (CDX) (10.5, Straumann Group, Basel, Switzerland) implant planning software proves useful in teaching.
Methods: Twenty students planned implant positions with CDX which were then placed in a model using printed drill templates in the sense of FG implantation (group 1) and HG implantation (group 2).
Ren Fail
December 2024
Department of Nephrology-Hemodialysis and Therapeutic Apheresis, Metz-Thionville Regional Hospital Center, Mercy Hospital, Metz, France.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!