Introduction: Clinical studies have indicated reduced reliance on blocking screws with the introduction of polyaxial locking nails, yet the biomechanical superiority of polyaxial locking over blocking screws remains unverified, specifically for distal dia-metaphyseal femur fractures.
Hypothesis: We hypothesized that the combination of multiaxial locking using three screws and parallel locking reinforced by two blocking screws would result in superior outcomes compared to utilizing only parallel locking with two screws and one blocking screw.
Materials And Methods: Third-generation custom-made femur models representing AO/OTA 32 A1.2 dia-metaphyseal comminuted oblique fractures were divided into four groups (n=10/group). Group A employed distal fixation with three 4.5-mm polyaxial screws. Group B used two parallel locking screws and two blocking screws, Group C used two parallel locking screws and one blocking screw, and Group D used only two parallel screws. Specimens underwent axial and torsional load testing to assess fatigue strength, ultimate strength, axial stiffness (N/mm), torsional stiffness (N/mm/deg), axial load to failure (N), torsional load to failure (N/mm), coronal and sagittal angulations, and fracture site collapse.
Results: Group C exhibited statistically superior torsional stiffness compared to Groups B and D (p=0.039 and p=0.034, respectively). Axial load to failure was highest in Group B and lowest in Group D (p=0.032). Group C demonstrated the highest torsional strength, while Group B exhibited the lowest (p=0.006). Coronal displacement was greatest in Group B, while Group A showed the highest resistance (p=0.009). Group A demonstrated the greatest resistance to fracture site collapse, with the weakest specimens observed in Groups B and C (p=0.01).
Discussion: The performance of a single laterally positioned blocking screw is comparable to using two blocking screws. Medial positioning of a second blocking screw is unnecessary for stability enhancement. Multiaxial locking prevents fracture site collapse and coronal plane angulation more effectively than other methods. Multiaxial locking and/or parallel screws with a single laterally positioned blocking screw provide superior stiffness and stability for treating unstable dia-metaphyseal distal femoral fractures.
Level Of Evidence: N/A.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.otsr.2023.103695 | DOI Listing |
Knee Surg Sports Traumatol Arthrosc
December 2024
Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Purpose: To biomechanically evaluate a flat posterior cruciate ligament (PCL) reconstruction utilizing rectangular femoral bone tunnels.
Methods: Eight fresh-frozen human knee specimens were tested in a six-degrees-of-freedom robotic test setup. In each testing step, a force-controlled test protocol was performed, including 89 N posterior tibial translation (PTT) in neutral, internal and external rotation, from 0 to 90° of flexion.
Clin Shoulder Elb
December 2024
Department of Trauma and Orthopaedic, The Royal London Hospital, London, UK.
Background: Iatrogenic suprascapular nerve injury secondary to posterior drilling or screw penetration is a recognized complication of bone block or coracoid process transfers for anterior glenohumeral instability. We present the first cadaveric study that assesses the safety of posteroanterior reference guides and quantifies the relationship of the suprascapular nerve to posterior glenoid fixation with suture buttons.
Methods: Anterior glenoid bone block reconstruction with suture buttons utilizing a posteroanterior reference guide was performed in 10 fresh frozen cadavers via a posterior portal.
Cureus
November 2024
Orthopaedics, Glasgow Royal Infirmary, Glasgow, GBR.
Osteoporosis is a major risk factor for fragility fractures. The British Orthopaedics Association Standards for Trauma and Orthopaedics (BOAST) and Getting it Right First Time (GIRFT) guidelines on fragility fracture management highlight the need to initiate prompt, coordinated multidisciplinary care with a focus on early mobilisation to improve patient outcomes. Medical management of fragility fractures focuses on the prevention of progressive frailty.
View Article and Find Full Text PDFJ Orthop Surg Res
December 2024
Department of Clinical Laboratory, Shengli Oilfield Central Hospital, No. 31 Jinan Road, Dongying, Shandong, 257034, China.
Background: To compare the efficacy of intramedullary nailing via the lateral parapatellar approach versus the infrapatellar approach in treating fractures at the tibial metaphyseal-diaphyseal junction.
Methods: A retrospective analysis was conducted on the clinical data of 45 patients with proximal or distal tibial fractures treated with intramedullary nailing via lateral parapatellar approach (n = 23) or infrapatellar approach (n = 22) between January 2019 and March 2023. We recorded and compared the operative time, intraoperative blood loss/fluoroscopies, success rate of closed reduction, anteroposterior and lateral entry point accuracy, postoperative infection, fracture healing time, as well as NRS pain scores, Lysholm knee function scores, and knee range of motion.
J Clin Med
December 2024
Clinic of Rehabilitation, Department of Traumatology, Orthopedics and Rehabilitation, Medical University of Lublin, 20-954 Lublin, Poland.
: Thoracolumbar and lumbar spine injuries account for 30-60% of spinal fractures, especially at the thoracolumbar junction. Conservative treatment is recommended for stable fractures without neurological symptoms, but studies suggest surgical intervention may offer better outcomes. However, there is no consensus on the best stabilization method.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!