Inspiris Resilia Valve in the Pulmonary Position: Modify or Abandon?

Ann Thorac Surg

The Children's Heart Clinic, Children's Minnesota, 2530 Chicago Ave South, Ste 500, Minneapolis, MN 55404. Electronic address:

Published: June 2024

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2023.09.030DOI Listing

Publication Analysis

Top Keywords

inspiris resilia
4
resilia valve
4
valve pulmonary
4
pulmonary position
4
position modify
4
modify abandon?
4
inspiris
1
valve
1
pulmonary
1
position
1

Similar Publications

Successful surgical repair of aortic root rupture during transcatheter aortic valve implantation: a case report.

Gen Thorac Cardiovasc Surg Cases

October 2024

Department of Cardiovascular Surgery, Hakodate Municipal Hospital, 1-10-1 Minato-cho, Hakodate City, Hokkaido, 041-8680, Japan.

Background: Aortic root rupture is a rare but potentially fatal complication of transcatheter aortic valve implantation (TAVI). Herein, we report a case of aortic root rupture during TAVI that was successfully managed with partial aortic root repair and aortic valve replacement.

Case Presentation: An 83-year-old woman with severe bicuspid aortic stenosis underwent transfemoral TAVI using a 26 mm SAPIEN 3 Ultra RESILIA valve.

View Article and Find Full Text PDF

Pannus formation: a rare culprit of early bioprosthetic valve dysfunction-a case report.

Eur Heart J Case Rep

October 2024

Department of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.

Background: Early bioprosthetic valve dysfunction (BVD) due to pannus formation is uncommon in elderly patients, and only a limited number of cases have been reported.

Case Summary: An 84-year-old man presented with exertional dyspnoea 3 years after surgical aortic valve replacement (SAVR) with a 19 mm Epic™ valve (Abbott, Santa Clara, CA, USA). Transthoracic echocardiography demonstrated progressive BVD, and cardiac computed tomography (CT) revealed sub-aortic pannus formation.

View Article and Find Full Text PDF

Background: Conventional stented, rapid deployment and new-generation stented valves are now available for surgical aortic valve replacement (SAVR). New-generation devices feature advanced tissue treatment for theoretical prolonged durability and a new stent design able to expand in case of future transcatheter Valve-in-Valve. Aim of this retrospective, multicenter, propensity-weighted study was to compare early clinical and hemodynamic outcomes of these three different bioprostheses.

View Article and Find Full Text PDF
Article Synopsis
  • The mitris valve combines features of two existing valves—the Carpentier-Edwards PERIMOUNT Magna Mitral Ease valve and INSPIRIS RESILIA tissue—for enhanced hemodynamic performance and durability.
  • Its design includes a more flexible, saddle-shaped sewing cuff that fits the mitral valve better, reducing risks of complications during double-valve replacements.
  • The valve also benefits from advanced technology that minimizes free aldehyde levels, suggesting improved long-term durability and reliability compared to earlier models.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to explore differences in characteristics and 2-year outcomes after surgical aortic valve replacement (SAVR) between males and females, using data from two registries involving 933 patients.
  • Females had certain clinical differences such as lower body mass index, higher surgical risk scores, and smaller valves compared to males, but these disparities largely disappeared after adjusting for similar baseline characteristics.
  • Ultimately, despite a higher initial surgical risk profile, both sexes had comparable outcomes 2 years post-SAVR, indicating no significant differences in overall results based on sex.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?