Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Three-dimensional (3D) ultrasonography is nonionizing and has been demonstrated to be a reliable tool for scoliosis assessment, including coronal and sagittal curvatures. It shows a great potential for axial vertebral rotation (AVR) evaluation, yet its validity and reliability need to be further demonstrated.
Materials And Methods: Twenty patients with adolescent idiopathic scoliosis (AIS) (coronal Cobb: 26.6 ± 9.1°) received 3D ultrasound scan for twice, 10 were scanned by the same operator, and the other 10 by different operators. EOS Bi-planar x-rays and 3D scan were conducted on another 29 patients on the same day. Two experienced 3D ultrasonographic researchers, with different experiences on AVR measurement, evaluated the 3D ultrasonographic AVR of the 29 patients (55 curves; coronal Cobb angle: 26.9 ± 11.3°). The gold standard AVR was determined from the 3D reconstruction of coronal and sagittal EOS radiographs. Intra-class correlation coefficients (ICCs), mean absolute difference (MAD), standard error measurements (SEM), and Bland-Altman's bias were reported to evaluate the intra-operator and inter-operator/rater reliabilities of 3D ultrasonography. The reliability of 3D ultrasonographic AVR measurements was further validated using inter-method with that of EOS.
Results: ICCs for intra-operator and inter-operator/rater reliability assessment were all greater than 0.95. MAD, SEM, and bias for the 3D ultrasonographic AVRs were no more than 2.2°, 2.0°, and 0.5°, respectively. AVRs between both modalities were strongly correlated ( = 0.901) and not significantly different ( = 0.205). Bland-Altman plot also shows that the bias was less than 1°, with no proportional bias between the difference and mean of expected and radiographic Cobb angles.
Conclusion: This study demonstrates that 3D ultrasonography is valid and reliable to evaluate AVR in AIS patients. 3D ultrasonography can be a potential tool for screening and following up subjects with AIS and evaluating the effectiveness of nonsurgical treatments.